Installation Sheet

Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Property Damage: Join remaining tube
to cold water supply only.
Turn on water supply.
Open hot water faucet to expel trapped air.
For the F-1000S and F-1000, flush
2.25 gallons through filter before use
(approximately 3 minutes). For the F-2000S
and F-2000, flush 3 gallons through filter
before use (approximately 4 minutes).
b
a
Featuring OptiPush
hot side activation with
automatic shut off and cool side Stay-On
, which
keeps the faucet open when dispensing cool water.
HC3300: To dispense instant hot water, first
press down on the faucet handle and then
push the handle backward in the direction of
the red indicator on the top of the handle.
To dispense cool water, first press down on
the faucet handle and then pull the handle
forward in the direction of the blue indicator
on the handle.
Note: Only applies when handle is mounted on
left side.
Featuring OptiPush
hot side activation with
automatic shut off.
H3300: To dispense instant hot water, first
press down on the faucet handle and then
push the handle backward in the direction of
the red indicator on the top of the handle.
6
Install a T-fitting (not included) onto the cold
water supply line.
Install dedicated water control valve with 1/4"
compression fitting.
At the end of the white 1/4" tube from the filter
or quick-connector, slide the supplied brass nut
and ferrule over the tube and then push in the
brass tube insert.
Insert the white 1/4" tube into the 1/4"
compression fitting and tighten.
If the water coming from the faucet is not hot 15 minutes after the unit has been
plugged in – or for other issues related to the operation of your instant hot water
dispenser – refer to the “Troubleshooting” section on Page 17.
FINAL WATER CONNECTION
c
Check all connections to ensure they are tight
and that there are no leaks.
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
Property Damage: A standard grounded outlet within
30” of the dispenser is required under the sink. Do not
use an extension cord set with the dispenser.
Operating Instructions for InDulge
TM
Modern Faucets
Dispensing Hot Water
(HC3300, H3300)
Dispensing Cool Water
(HC3300)
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
11
NOTICE
NOTICE