Installation Sheet

Electric Shock Hazard: To prevent electrical shock, disconnect power before
servicing unit. Use only a properly grounded and polarized electric outlet.
CARE AND USE
Scalding Hazard: Do not allow
water to boil. May result in
severe burns.
Factory temperature pre-set is 200˚F.
To reset the thermostat to 200°,
turn the indicator two notches to
the right of vertical.
Adjust the thermostat
slowly, turning the dial
clockwise to increase
temperature or counter
clockwise to decrease temperature, then
activate faucet handle for 20 seconds to
bring in fresh water to be heated at the new
setting. Allow 5-7 minutes for water to reach
new temperature.
ADJUSTING THE THERMOSTAT
CLEANING THE FAUCET AND TANK
Replace filter cartridge when there is an obvious decrease
in water flow to the faucet or if there is an objectionable
taste or odor to the water.
When the inlet and outlet ports have been closed and
the filter’s internal pressure has been relieved, water
(about 2 oz) will discharge from vent line.
If the new filter cartridge cannot be inserted, insert the
old one and turn until it stops, remove it and then retry
the new cartridge.
Carbon filters should be replaced within 6 months.
FILTER GUIDE AND REPLACEMENT
Filter replacement instructions:
Replace with an InSinkErator
®
filter.
Place pan or dish towel under the filter to
catch water drainage during change.
Slowly turn the cartridge counter-clockwise
completely until it stops (1/4 turn).
Pull cartridge straight down and discard.
Insert new cartridge into filter head.
Top surface of cartridge will become flush
with the bottom of the filter head when
fully engaged.
Turn the cartridge clockwise until it stops
(1/4 turn).
Align the in/out arrow on the head and
bracket assembly to the in/out arrow on
the cartridge.
Open faucet to expel trapped air.
For the F-1000S and F-1000, flush
2.25 gallons through filter before use
(approximately 3 minutes). For the F-2000S
and F-2000, flush 3 gallons through filter
before use (approximately 4 minutes).
Regularly inspect the unit for any signs of
leakage. If there are signs of water damage,
immediately remove the unit from service.
To avoid water damage from leakage,
replace all cut, loose or split tubing.
A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector,
should be used in those applications where
any leakage could cause
property damage.
PROPERTY DAMAGE
Anytime the instant hot water dispenser is not used for
extended periods of time, unplug and drain unit. If it is below
freezing you will need to unplug the unit and drain it.
Disconnect power from unit (unplug unit).
Push hot water dispenser faucet lever and
allow water to flow until it is cool.
Shut the cold water supply off at the valve.
Disconnect tubes from the tank.
Unhook tank from wall.
Hold tank upside down and drain the water
into the sink.
Towel dry any water drippings from tank area.
Reinstall tank to wall and reconnect tubes.
Remove and discard filter cartridge,
if applicable.
To put back into working order, install new
filter cartridge (if applicable) and turn on cold
water supply at valve. Depress the hot water
dispenser faucet lever and hold until water
flows from the spout. Reconnect the
electrical cord. (Refer to Page 11, Step 6B)
SEASONAL STORAGE/DRAINAGE
approx. 200°
Regularly check for signs of corrosion
by examining the appearance of the
dispensed water.
If there is any discoloration or rusty appearance,
unplug and drain unit as described in the
Seasonal Storage/Drainage section on this
page of the manual.
If the water discoloration remains after
draining and refilling unit, discontinue use
and contact an authorized InSinkErator
service agent.
PERSONAL INJURY
15
Only use mild cleaners to clean the faucet
and plastic components.
Cleaners with acids, abrasives, alkaline or
organic solvents will result in deterioration of
the plastic components and void the warranty.