Installation Sheet

a
Select a spot under the sink to mount
tank vertically within reach of both
plumbing and electrical connections.
The tank should be within 16" or less
of faucet water lines and within 30"
or less of a standard grounded outlet.
While holding tank in place on
the spot selected for installation,
use a pencil to mark locations for
2 hanging screws.
Property Damage: Tank must be located
within 16" of faucet and within 30" or less
of a standard grounded outlet. DO NOT
extend plumbing or electrical lines.
3
Tank must be
mounted level
to ensure
proper operation.
Mount tank vertically in an area that allows clear-
ance on the underside of the tank for drainage, if
necessary.
DO NOT over tighten screws.
Pre-drill 1/8" pilot holes at marks.
Turn screws into pre-drilled holes,
leaving 1/4" exposed.
Hang the tank on the screws.
Tighten the screws with only
1/2 turn clockwise.
b
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
Leave 1/4" for
hanging tank.
Without depressing the gray button,
place the snap-connect fitting at
the end of the blue or copper 1/4"
tube onto the left fitting on the tank,
pushing until it clicks into place. (1)
Slip the flexible white 7/16" tube
over barbed steel fitting and slide
down approximately 1/2". (2)
Note: Snap-connect fitting not
included.
Slip the clear 5/16" tube over the
smooth plastic fitting and slide down
approximately 1/2". (3)
Check for pinched or crimped tubes.
4
a
Property Damage: Pinched or blocked water lines
may cause damage to the dispenser tank. Check
to make sure tubes are connected properly and
are pushed down as far as possible.
Hose clamps are not needed for any
of the connections.
MOUNTING THE TANK
CONNECTING FAUCET TO TANK
9
Do not plug in the HWT-F1000S Until Step 6C.
NOTICE
NOTICE