Installation Guide

14
TROUBLESHOOTING
WHAT TO DO
Water and steam spits
forcefully from spout
without turning on the
dispenser faucet.
Water is not hot.
Unit is boiling.
May be normal during initial setup.
• The unit is unplugged.
The electric outlet is inoperative.
Activate faucet lever to release some water from
the tank.
Adjust water temperature using dial on tank front.
Remember that at higher altitudes, water boils
at lower temperatures.
Make sure the unit is connected to a properly
grounded electric outlet.
Make sure the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
Water is too hot
or not hot enough.
Thermostat is not adjusted to
your needs.
Adjust the thermostat slowly, then activate faucet
lever for 20 seconds to bring in fresh water to be
heated at the new setting. Allow 5-7 minutes for
water to reach new temperature.
Water comes out the
vent instead of spout.
• Outlet tube is blocked. Check that outlet tube is not kinked, twisted
or pinched.
Unscrew spout end piece and clean out any debris.
Water is dripping from
the spout/vent
intermittently.
The expansion chamber isn’t
draining properly due to low
water pressure.
• The spout is blocked.
Unplug the unit. If the dripping doesn’t stop after a
few minutes, check the supply valve to ensure that
is fully open and there are no obstructions in the
water line reducing the pressure below 30 psi (i.e.,
a poorly mounted saddle valve, a clogged water
filter, or a partially opened shut-off valve).
Unscrew spout end piece and clean out any debris.
Water is dripping
from the spout/vent
constantly.
Debris in the water line may
be in the faucet valve seat
causing a slow water leak.
Unscrew spout end piece and clean out any debris.
Activate faucet lever 7-10 times to flush faucet & lines.
Divided stream.
Debris in the end piece. Unscrew spout end piece and clean out any debris.
Water continues to run
after releasing lever.
(View/Wave)
Mounting nut too tight.
Mounting washers not
installed properly
Loosen mounting nut, 1/4 turn at a time, until
shut-off occurs.
See page 6, Step 2B to check proper mounting
washer installation.
PROBLEM POSSIBLE CAUSE
If you are still experiencing trouble call the AnswerLine
®
1-800-558-5700.
Please read Troubleshooting Guide and/or visit
www.insinkerator.com before calling AnswerLine
®
Water discoloration/
rusty appearance.
Corrosion of unit. Unplug and drain unit as described in the Seasonal
Storage/Drainage Section on page 13 of this
manual. If the water discoloration remains after
draining and refilling unit, discontinue use and
contact an authorized InSinkErator service agent.
INVOLVE VIEW
INVOLVE WAVE
INVITE CONTOUR
INVITE CLASSIC
INVITE HOT100
INVITE HOT150
Instalación, cuidado y uso
Dispensador de agua caliente instantánea
Manual del usuario
INVOLVE VIEW
INVOLVE WAVE
INVITE CONTOUR
INVITE HOT100
INVITE HOT150
INVITE CLASSIC