Use Instructions

20
ENGLISH
Slide cable diameter .......................
ø 7.0 mm
Working range ................................
Ø 40 - 110 mm
Positioning transmitter
.......................
3
3 kHz
Protection class
camera head
............
I
P 68
Included in delivery: ROCAM mini HD TV-
inspection system with Camera head ø25 mm, guide
ball, USB cable, test adaptor, manual, SD card, battery and charger.
3 Technical Data charger and battery (B)
Battery: Charger:
U = Voltage U1 = Input voltage
C = Capacity f1 = Input frequency
W = Weight P1 = Input power
Ic = Charge current U2 = Charging voltage
t
= Approx. charging time (90% full) I2
= Max. charge current
Charging voltage
.............................
20,75 V DC Nc = No. of battery cells
Charging temperature ..
0° - 50° C, 32° - 122° F
W = Weight
Max. discharging
temperature.
................................
5° - 50° C, 41° - 122° F
Pay attention to the electrical outlet
voltage! Check the label on the
bottom of the charger!
Recharge battery pack before first use!
4 Function of the Unit
4.1 Overview (A)
1 Camera head 7 Frame
2 Positioning probe 8 Holder
3 Bending spring 9 Monitor cable
4 Reel cable 10 Monitor bracket
5 Monitor unit 11 Battery release
6 Reel 12 Battery
4.2 Working notes
- Do not bend the reel cable! The cable may break!
- Do not pull the reel cable over sharp edges! The cable may become damaged!
A
TTENTION! Always protect ROCAM mini HD against water, and use only recom-
mended indoors. Only the camera head (1) and reel cable (4) may come into contact
with water
!
4.3 Changing the battery
Insert the battery into the receptacle on the back of the frame (7) until it clicks into place. To
remove, press the battery release (11) and pull the battery out.
4.4 Working with the device
Wear protective clothing! Always stand next to the reel cable!
Push reel cable (4) with bending spring (3) from the holder (8).
Remove the cap from the camera head (1) and screw on the bending spring (3).
Caution: Check for cleanliness and damage!
If necessary, additional accessories can be attached to camera. When using pipe diameters
greater than 70 mm, always use guide body!
Clean the pipe system before inspection.