240V 30A Load Controller INSTEON® 240V 30 Amp Load Controller (Dual-Band) Model : 2477SA1 (Normally Open) 2477SA2 (Normally Closed)
40V Load Controller Owner’s Manual 240V Load Controller Owner’s Manual TABLE OF CONTENTS ABOUT 240V LOAD CONTROLLER........................................................................................................... 3 Key 240V Load Controller Features .......................................................................................................... 3 WHAT IS INSTEON? .............................................................................................................................
240V Load Controller Owner’s Manual ABOUT 240V LOAD CONTROLLER 240V Load Controller lets you efficiently control the use of heavy-duty appliances to save energy and cut down on utility costs. Remotely control your appliances that run on higher voltages, up to 30 Amps (resistive loads only).
240V Load Controller Owner’s Manual WHAT IS INSTEON? Since its inception in 2005, INSTEON has become the industry gold standard in home-control networking technology, offering more reliability and flexibility than any other home management system on the market. INSTEON is simple, reliable and affordable. • Simple: each device takes just minutes to install. • Reliable: every INSTEON device works as a network repeater, ensuring your commands will not be lost.
240V Load Controller Owner’s Manual INSTALLATION Tools You Will Need • Screwdriver (to remove the cover of the junction box) • Wire cutter/stripper • Various tools to wall-mount 240V Load Controller Preparing to Install 240V Load Controller CAUTION Read and understand these instructions before installing and retain them for future reference.
240V Load Controller Owner’s Manual Installing 240V Load Controller 1) At the circuit breaker or fuse panel, disable the circuit supplying power to the electrical junction box that is wired to the appliance you wish to control with 240V Load Controller. 2) Remove the cover of the junction box and disconnect the two supply lines coming from the circuit breaker, ensuring that you have ½” of bare wire on the ends.
240V Load Controller Owner’s Manual CONTROLLING 240V LOAD CONTROLLER FROM AN INSTEON CONTROLLER Linking an INSTEON Controller to 240V Load Controller To use 240V Load Controller as a responder to an INSTEON controller, follow these steps to link 240V Load Controller and the controller together. Refer to the controller’s Owner’s Manual for detailed instructions on how to properly install and link it to 240V Load Controller.
240V Load Controller Owner’s Manual CONTROLLING INSTEON RESPONDERS FROM 240V LOAD CONTROLLER Linking 240V Load Controller to an INSTEON Responder To use 240V Load Controller as an INSTEON controller, follow these steps to link 240V Load Controller and an INSTEON responder (the device you wish to control with 240V Load Controller) together. Refer to the responder’s Owner’s Manual for detailed instructions on how to properly install and link it to 240V Load Controller.
240V Load Controller Owner’s Manual CREATING AN INSTEON SCENE INSTEON scenes let you activate dramatic lighting moods with the press of just one button. For example, you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with the tap of a button on a controller. INSTEON scenes are very easy to set up – just link more than one responder to the same On/Off or Scene button on a controller.
240V Load Controller Owner’s Manual X10 PROGRAMMING OPTIONS 240V Load Controller is X10 ready, meaning that it can respond to X10 commands from X10 controllers and it can send commands to X10 devices. However, to operate 240V Load Controller in X10 mode, you must first set up an X10 address. As it ships from the factory or after a factory reset procedure, 240V Load Controller will not have an X10 address set up.
240V Load Controller Owner’s Manual The majority of single-family homes in North America have two phases (or “legs”) of 110 Volts coming into their electricity panels. From the panel, they are distributed throughout the home, providing power to outlets and wall switches. These phases come together in some parts of the home to provide 220 Volts of power to large appliances, such as an electric oven or pool pump.
240V Load Controller Owner’s Manual Problem Possible Cause Solution Make sure the circuit breaker is turned on. The Status LED on 240V Load Controller is 240V Load Controller may not turning on and not be getting power. won’t control the load. The load is not being controlled after I’ve linked 240V Load Controller to a controller. Check the junction box wires to ensure all connections are tight and no bare wires are exposed.
240V Load Controller Owner’s Manual SPECIFICATIONS, CERTIFICATION, AND WARRANTY Specifications View specifications for 240V Load Controller (Normally Open) at: www.smarthome.com/2477SA1.html or 240V Load Controller (Normally Closed) at: www.smarthome.com/2477SA2.html Certification This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent thirdparty testing laboratory.
240V Load Controller Owner’s Manual Limited Warranty Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect.