On/Off Module Owner’s Manual 2633-422 (France) 2633-432 (Germany) 2633-442 (UK) 2633-452 (Chile) 2633-522 (AUS/NZ) Page 1 of 14 2633-432 (Germany) 2633-452 (Chile) 2633-422 (France) 2633-442 (UK) 2633-522 (Aus/NZ) Rev: 1/21/2014 7:47 AM
TABLE OF CONTENTS About On/Off Module .................................................................................................................................. 2 Features and Benefits ............................................................................................................................... 3 Installation ...................................................................................................................................................
Features and Benefits - Integrated on/off relay Compatible with all INSTEON (and X10) controllers; can also act as an INSTEON (and X10) controller Super-easy setup with multi-color LED and beeper Dual-band communicates simultaneously over both RF and powerline Stores setup state in non-volatile memory so settings aren’t lost during power outages Two-year warranty Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference.
Using On/Off Module Paddle On/Off Module’s paddle will control the load and any additional linked responders with tap, double-tap and press and hold actions to initiate different behaviors.
Beep on Button Press Default = disabled This setting is only adjustable via software or a central controller. On/Off Module will beep every time its paddle is tapped. INSTEON Setup Some products have subtle differences in their setup procedures. Please refer to the other devices’ owner’s manuals for details. INSTEON Controllers, Responders and Links Let’s define a few terms.
Make On/Off Module a Controller 1) Press and hold On/Off Module set button until it beeps On/Off Module LED will start blinking green You will have four minutes to complete the next steps before linking mode times out 2) Adjust responder to desired state 3) Press and hold responder set button until it double-beeps 1 On/Off Module will double-beep and its LED will stop blinking 4) Test link by tapping or pressing and holding On/Off Module paddle to turn on/off or brighten/dim Responder will respond appropri
3) Adjust On/Off Module to desired level (on or off) 4) Press and hold On/Off Module set button until it double-beeps 5) For each additional scene member: a) Adjust member to desired scene brightness b) Press and hold set button until it double-beeps 6) Tap controller set button Controller will beep and LED will stop blinking 7) Test by tapping controller button on and off On/Off Module and other scene responders will all respond appropriately Make On/Off Module a Controller of Multiple Responders 1) Press
Remove On/Off Module as a Controller of Multiple Responders 1) Press and hold On/Off Module set button until it beeps LED will start blinking green 2) Press and hold On/Off Module set button until it beeps a second time LED will start blinking red 3) Tap On/Off Module set button LED will start double-blinking red 4) For each responder you are removing: a.
Example: A1-OFF-A1-OFF-A1-OFF or A1-A1-A1-AOFF On/Off Module will double-beep and LED will stop blinking 4) Test by sending X10 on and off commands On/Off Module will not respond Specifications General Product name On/Off Module Brand/manufacturer INSTEON Manufacturer product number 2633-422 France 2633-432 Germany 2633-442 UK 2633-452 Chile 2633-522 AUS/NZ UPC 813922012651 France 813922012668 Germany 813922012675 UK 813922014112 Chile 813922012682 AUS/NZ Warranty 2 years, limited INSTEON INSTEON
Commands supported as responder On Off Fast-on Fast-off Beep Software configurable Yes RF range Up to 50 meters (150 feet) open air Phase bridge detect beacon Yes INSTEON device category 0x02 appliance control INSTEON device subcategory 2633-422 (France, 869.85 MHz) 2633-432 (Germany, 869.85 MHz) 2633-442 (UK, 869.85 MHz) 2633-452 (Chile, 915 MHz) 2633-522 (Aus/NZ, 921.
Electrical Voltage 100VAC to 240VAC (+/- 10%) Frequency 50/60Hz auto detected at power-up 16A – 240VAC (EUR) 10A – 240VAC (AUS/NZ) Maximum load 3600W/240VAC Resistive 700W/240VAC Inductive/Capacitive 2000W/240VAC Bulbs/Low Voltage Halogen Minimum load N/A Resistive Load type(s) Inductive/capacitive Low voltage halogen Hardwired remote control N/A Retains all settings without power Yes, saved in non-volatile EEPROM Standby power consumption < 0.
Other electrical devices, such as computers, televisions or power strips, may be absorbing the INSTEON signal The controller may be sending commands to a responder that is no On/Off Module is taking a long time longer in use. Commands to respond to a controller for the unused responder are being resent and slowing down the network Remove from the scene any unused responders from the controller.
INSTEON products or buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to see if your devices are within communication range. You will need at least one other INSTEON dual-band device installed.
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities.