® INSTEON On/Off Module 2635-222 Owner’s Manual
Contents Getting Started INSTEON On/Off Module 4 Device Overview Buttons Installation Leave Your Appliance On INSTEON Links Understanding Linking 6 Links are One-Way Links Remember a Device’s State Controllers Responders Controller-Only 7 Responder-Only Grouping Devices Use Cross Linking Linking to the INSTEON Hub Linking with a Single-Button Controller Linking with a Multi-Button Controller Multi-Linking or Making a Scene Unlinking from a Single-Button Controller Unlinking from a Multi-But
Getting Started Everything you need to quickly get up and running.
INSTEON On/Off Module Device Overview On Off Buttons Status LED Tap to turn on For dimmable responders: Double-tap to turn on instantly Press and hold to brighten Tap to turn off On Off Set Button ® Installation Plug your appliance into the bottom of the On/Off Module and plug the On/Off Module into an unswitched wall outlet.
INSTEON Links INSTEON devices can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to form a control system. Most INSTEON devices can control one another and be the recipient of control. The process of associating multiple INSTEON devices to one another is called Linking.
Understanding Linking Links are One-Way When linking INSTEON devices, the links that are created are one-way. Links Remember a Device’s State The current state of the controlled device is stored in the link: on, off or dimmed. NEW NEW 75% ® A B Switch Switch A will turn Switch B on and off but Switch B cannot turn Switch A on or off. X Controllers INSTEON devices that can turn other devices on or off are called controllers.
Understanding Linking Controller-Only Some devices like sensors can only control other devices. Responder-Only Some devices cannot control other devices; these devices only receive INSTEON commands. NEW NEW X X ® Motion Sensor Dimmer Switch The Motion Sensor will turn on the Switch but the switch cannot control the Motion X Sensor. Grouping Devices You may want to group together two devices, for example, in a virtual-three way configuration. For INSTEON, this is called Cross Linking.
Linking to the INSTEON Hub 1 From Rooms, navigate to All Devices. 2 Tap the Add button. All Devices Rooms All Devices Check-In Favorites Back Door Bathroom Bedroom Bathroom Bedroom Hallway Font Door Garage Door Garage Light Kitchen Living Room Outside Motion Sensor Outside Lights 72º 72º 3 Add Select Plug-In Module form the list of devices. 4 When prompted, press and hold the set button on your On/Off Module until the device double-beeps.
Linking with a Single-Button Controller 1 On your INSTEON controller, press and hold the set button until the device beeps. 2 Make sure the On/Off Module is On and then press and hold the On/Off Module’s set button until the device double-beeps. ® NEW ® Your INSTEON controller will now control your On/Off Module.
Linking with a Multi-Button Controller 1 On your INSTEON controller, tap the desired control button and then press and hold the set button until the device beeps. 2 Make sure the On/Off Module is On and then press and hold the On/Off Module’s set button until the device double-beeps. A ® B NEW ® Your INSTEON controller will now control your On/Off Module.
Multi-Linking or Making a Scene 1 On your INSTEON controller, press and hold the set button until the device beeps, then tap the set button. 2 A Adjust your scene members to their desired state: on, off, or brightness level if dimming. 50% 72% Lamp 1 Lamp 2 30% ON Lamp 3 Appliance B 3 One at a time, press and hold the set button on each scene member until it double-beeps. 4 Tap the set button on your INSTEON controller to finish building your scene.
Unlinking from a Single-Button Controller 1 3 On your INSTEON controller, press and hold the set button until the device beeps. 2 Press and hold the set button again until the device beeps. Press and hold the On/Off Module’s set button until the device double-beeps. NEW X ® ® Your INSTEON controller will no longer control your On/Off Module.
Unlinking from a Multi-Button Controller 1 On your INSTEON controller, tap the desired control button and then press and hold the set button until the device beeps. 2 Press and hold the set button again until the device beeps. A B 3 Press and hold the On/Off Module’s set button until the device double-beeps. NEW X ® ® Your INSTEON controller will no longer control your On/Off Module.
Multi-Unlinking or Removing a Scene 1 On your INSTEON controller, press and hold the set button until the device beeps. Press and hold the set button again, then tap the set button. 2 One at a time, press and hold the set button on each scene member until it double-beeps. A B ® C 3 Tap the set button on your INSTEON controller to exit MultiUnlinking mode. ® NEW X ® ® Your INSTEON controller will no longer control your INSTEON responders.
Local Programming Use local the local programming programming to set to local set local on-level, on-level, ramp ramp rates rates andand eveneven perform perform a factoryareset. factory reset.
NEW About Local Programming Local Programming The Programming Wheel is a visual representation of the device’s settings. Many device features can be configured using the Programming Wheel. Some devices have more options than others but the programming wheel presents even the most complicated devices with a straightforward, navigable path.
Local Programming Flow Chart Linking Mode Press Unlinking Mode Press Press ® Press Exit MultiUnlinking Mode Select Tap Select Tap Tap Multi-Linking Mode Press Exit Tap Exit Exit Press Select LED Brightness Adjust Tap Tap LED Brightness Press Cancel Tap Save RF Beacon Press RF Beacon Toggle Press Cancel Tap Tap Toggle Factory Reset Select Press Reset Tap Cancel 17
Software-Only Features Most INSTEON devices contain features that can only be enabled, disabled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem or the INSTEON Hub.
Software-Only Features Beep on Button Press The On/Off Module will beep every time one of its buttons are tapped. By default, this feature is disabled. Disable Local Programming Prevents changing any settings using the set button or tap-and-hold programming. By default, this feature is disabled. X ® Blink on Traffic The On/Off Module LED will blink if it detects INSTEON communication. By default, this feature is disabled.
Appendix Everything else you might need to know about your INSTEON product.
INSTEON Glossary Controller Responder Blinking The INSTEON transmitter The INSTEON receiver LED turning on and off repeatedly Dual-Band An INSTEON device that can send and receive both INSTEON powerline signals and INSTEON radio frequency signals Ramp Rate The speed at which the load fades on or off On-Level The preset brightness level a device will return to when turned on INSTEON A dual-band, mesh networking technology developed by Smarthome/INSTEON.
Specifications General Available Colors White Brand: INSTEON FCC ID SBP26352 Industry Canada Manufacturer Product No.: Patent No.: 5202A-26352 2635-222 Protected under US and Foreign Patents (see www.insteon.
Maximum Scene Memberships 400 Multi-Link Support Yes Multi-Unlink Support Yes RF Beacon Yes Radio Frequency Radio Frequency Range Scene Commands Supported as Controller Scene Commands Supported as Responder 915.
Electrical Controlled Outlet Hardwired Remote Control Load Types Yes, grounded. NEMA 5-15 type No General Appliances 15A Max Resistive 15A Max Incandescent 1,800W Max Motors 1HP Max Ballasts 10A Max Maximum Load 1,800 Watts (15 Amps) Minimum Load None Pass-through Outlet No Power Consumption <0.
Troubleshooting On/Off Module LED does not turn on It is possible your On/Off Module is not receiving power. If the attached load can still be controlled, It is possible that the status LED has been disabled. Try this: • Test On/Off Module in a different power outlet. If the LED illuminates when using a different outlet, check the original outlet for power. Some outlets are controlled by a switch elsewhere in the room. Avoid switched outlets as they disable your INSTEON device when turned off.
Troubleshooting The connected appliance turned on by itself There must be a device in your INSTEON network that is unexpectedly linked to the On/Off Module Try this: • Use software to examine the On/Off Module’s links. If you can identify the stray controller, remove the link. • If you are unable to identify the unexpected controller, perform a factory reset on the On/Off Module.
Certifications and Warnings Read and understand these instructions before installing and retain them for future reference. This product is not designed or approved for use on powerlines other than 120VAC, 50Hz or 60Hz, single phase. Attempting to use this product on unapproved powerlines may have hazardous consequences. • Use only indoors or in outdoor rated box • This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards.
Product Warranty Limited Warranty Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect.