On/Off Outlet Owner’s Manual
Contents Getting Started Insteon Wall Outlet 4 On/Off Outlet Buttons Tools Needed for Installation Disconnect Power Installation Timeline Installation Installation Diagrams End-of-Run Outlet Middle-of-Run Outlet Switched Outlet Insteon Links Understanding Linking Adding to the Insteon Hub Software-Only Features Beep on Button Press 6 10 11 12 15 17 19 Blink on Traffic Disable Local Programming Error Blink LED Brightness Local Programming Flow Chart LED Brightness RF Beacon Load Sense Soft F
Getting Started Everything you need to quickly get up and running.
Insteon Wall Outlet On/Off Outlet Buttons Tap to turn the upper outlet on or off. Status LEDs On Upper Outlet Upper Tamper Resistant Off On/Off & Set Buttons See sections on Basic Linking and Local Programming for additional set button functions. Tap to turn the lower outlet on or off. Lower Outlet Tamper Resistant Tools Needed for Installation Lower See sections on Basic Linking and Local Programming for additional set button functions.
Installation Timeline Unbox and read instructions Disconnect Power Remove the old outlet Reconnect Power Identify Line wire Disconnect Power Connect the outlet wires to the junction box wires Carefully install the outlet into the junction box Reconnect Power Test the outlet by tapping a set button to turn on Install wall plate 5
Installation Disconnect Power 1 Turn off power to your outlet at the electrical service panel. ON Remove the Old Outlet 2 ON 1 or Circuit Breakers Remove the old outlet and disconnect the wires. 2 Fuse Panel ½” 12mm Reconnect Power 3 Turn on power at the circuit breaker. ON ON Identify Line 4 Use a voltage detector to identify the line wire. Line will be energized.
Installation Wire-In the Outlet 5 Turn off power at the circuit breaker. Connect the Outlet wires to the identified wires in the junction box. Verify that the wire nuts are secure and that no exposed copper wire is visible. Additional wiring diagrams can be found in the Installation Diagrams section. Neutral Ground Line Install the Outlet 6 Mount the Outlet into the junction box. Reconnect Power 7 Turn power on to the outlet at the circuit breaker panel.
Installation Test the Outlet 8 Test your Outlet by tapping one of the set buttons to turn On and Off. Install Wall Plate 9 Complete installation by reattaching your wall plate. For the best look, us an INSTEON Screwless Wall Plate. On Off Installation of your Wall Outlet is now complete.
Installation Diagrams Use the installation diagrams in this section to help you wire your Wall Outlet.
End-of-Run Outlet Line Neutral Ground 10
Middle-of-Run Outlet Line Neutral Ground 11
Switched Outlet Without Insteon Wall Switch Replacing a switched outlet requires removing the wall switch from the circuit. The wall switch can be replaced by an Insteon Wall Switch or Keypad if control is still desired.
Switched Outlet With Insteon Wall Keypad Line Neutral Ground Line Neutral Ground 13
ChapterLinks Insteon Title Chapterdevices Insteon explanation can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to form a control system. Most Insteon devices can control one another and be the recipient of control. The process of associating multiple Insteon devices to one another is called Linking.
Understanding Linking Links are One-Way When linking Insteon devices, the links that are created are one-way. Links Remember a Device’s State The current state of the controlled device is stored in the link: On, off or dimmed. NEW NEW 75% A B Switch A will turn Switch B on and off but Switch B cannot turn Switch A on or off. X Controllers Insteon devices that can turn other devices on or off are called controllers.
Understanding Linking Controller-Only Some devices, like sensors, can only control other devices. Responder-Only Some devices cannot control other devices; these devices only receive Insteon commands. NEW Motion Sensor NEW Dimmer Switch The Motion Sensor will turn on the Switch but the switches cannot control the Motion X Sensor. Grouping Devices You may want to group together two devices, for example, in a virtual-three way configuration. For Insteon, this is called Cross Linking.
Adding to the Insteon Hub 1 Tap the Add a Device button. iOS Android Open the drawer by swiping from the right side of your iOS device Navigate to All Devices from Rooms on your Android device 2 Windows Phone Navigate to All Devices from Rooms on your Windows Phone device When prompted, press and hold one of the set buttons on your Wall Outlet until the device beeps. Your Wall Outlet is now added to your Insteon Hub.
Chapter Title Features Software-Only Chapter Most Insteon explanation devices contain features that can only be enabled, disabled or modified using Insteon control software such as HouseLinc and an Insteon PowerLine Modem.
Software-Only Features Beep on Button Press The Wall Outlet will beep every time one of its buttons are tapped. By default, this feature is disabled. Disable Local Programming Prevents changing any settings using the set button or tap-and-hold programming. Blink on Traffic The Wall Outlet LED will blink if it detects Insteon communication. By default, this feature is disabled.
Software-Only Features LED Brightness Adjust the brightness of the status LEDs from full bright to off.
Chapter Local Programming Title Chapter explanation Encompassing all on-device programming options, use the local programming to set local properties. properties and For factory the bestreset. experience, For the use best experience, software for use managing software device for managing properties. device properties.
Navigating the Chart To move right, press and hold the set button Status LED blinks green Status LED doubleblinks green To move down, tap the set button Status LED blinks red Status LED double-blinks red Features Linking Mode Multi-Linking Mode Unlinking Mode Multi-Unlinking Mode Readies the module for linking to another Insteon device. As linking is directional, the first device placed into linking mode will become the controller in the controller/ responder relationship.
Flow Chart Linking Mode Press Unlinking Mode Select Tap Tap Multi-Linking Mode Press Press Exit Multi-Unlinking Mode Select Press Exit Tap Tap Exit Exit 23
LED Brightness Upper set button only For a bright status LED, make sure the upper LED is green. Linking Mode Unlinking Mode Press Press Status LED Brightness Press Status LED Brightness Bright Bright For a dim status LED, make sure the upper LED is red.
Load Sense Enable Linking Mode Tap 3x Quickly Enable Load Sense Load Sense Disable Linking Mode Tap 2x Quickly Disable Load Sense 25
Soft Factory Reset Upper and lower set buttons A Soft Factory Reset will erase all device settings including any links made with the top and bottom outlets. If On/Off Outlet does not respond, attempt the Alternate Factory Reset.
Chapter Reset Factory Title Chapter A factoryexplanation reset will erase all links stored in the device’s database as well as any customized properties.
Factory Reset Alternate Procedure Factory Reset will erase all device settings including any links made with the top and bottom outlets 1 2 Press and hold the upper set button. Turn off power to your outlet at the electrical service panel. ON ON or Circuit Breakers Fuse Panel An assistant will be required to turn power on and off at the service panel. 3 Have your assistant turn power on to the outlet at the circuit breaker panel while continuing to press and hold the set button.
Appendix Everything else you might need to know about your Insteon product.
Specifications General Brand: Insteon FCC ID SBP26632 Industry Canada Manufacturer Product No.: Patent No.: UPC: Warranty: 5202A-26632 2663-222 White 2663-223 Ivory 2663-224 Almond 2663-225 Light Almond 2663-226 Black 2663-227 Brown 2663-228 Grey Protected under US and Foreign Patents (see www.insteon.
Insteon Powerline Device Insteon Powerline Frequency Yes 131.65 KHz Insteon RF Device Yes Maximum Controlled Scenes 400 Maximum Scene Memberships 400 RF Beacon Yes Radio Frequency Radio Frequency Range 915.
Electrical Power Consumption <0.4 Watts Supply Voltage 120 Volts AC, 50/60 Hertz, single phase Maximum Load 600W Incandescent 15A All Other Loads Surge Resistance Surges over 1000 volts Power Connector NEMA 5-15R Certification FCC ID Part 15B & 15C IC RSS-210 Issue 8 UL-498 Safety standard for receptacles CSA C22.2 #42 Including sections 131-135 for tamper-resistant outlets UL-244A, CAN/CSA C22.
Troubleshooting The LED lights on the Wall Outlet are not illuminated It is possible that your outlet is not getting power or that the status LEDs have been disabled. Try this: • Check to make sure power is flowing to your Insteon Wall Outlet. If your outlet was just installed, make sure the circuit breaker controlling the switch has been turned on. It is also advisable to verify the wire connections in the junction box are secure and not showing any bare wire.
Troubleshooting The connected light turned on by itself There must be a device in your Insteon network that is unexpectedly linked to the Wall Outlet. Try this: • Use software to examine the Wall Outlet’s links. If you can identify the stray controller, remove the link. • If you are unable to identify the unexpected controller, perform a factory reset on the Wall Outlet. This will remove all links from the module’s database but will also require that you reconfigure the device’s scenes and properties.
Certifications and Warnings This product is not designed or approved for use on powerlines other than 120VAC, 50Hz or 60Hz, single phase. Attempting to use this product on unapproved powerlines may have hazardous consequences. • Use only indoors or in outdoor rated box • This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible.
Product Warranty Limited Warranty Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect.