Open/Close Sensor Owner’s Manual 2843-222 (US) Rev 1.
About Open/Close Sensor ............................................................................................................................................ 2 Open/Close Sensor Hardware ..................................................................................................................................... 3 Installation .....................................................................................................................................................................
Open/Close Sensor Hardware Reed Switch Detects whether magnet is within ½” of the main case: • Closed state when magnet is within ½” • Opened state when magnet is further than ½” Set Button • Links other Insteon devices (responders) • Controls linked responders (scene 1): Tap to toggle between on and off External Sensor Terminals When using an external sensor, Open/Close Sensor is in closed state when either external sensor terminals or reed switch are closed.
Otherwise, move sensor and magnet closer together when closed and test again Connecting an External Sensor to Open/Close Sensor NOTE: For basic use of Open/Close Sensor’s external sensor terminals, it is not recommended to also use Open/Close Sensor’s internal reed switch to help ensure desired behavior. If connecting multiple sensors to Open/Close Sensor’s external sensor terminals and/or using Open/Close Sensor’s reed switch in addition to an external sensor, see Advanced External Sensor Use.
- To add multiple responders, repeat steps 2-4 or see Make Open/Close Sensor a Controller of Multiple Responders Make Open/Close Sensor a Controller of Multiple Responders 1) Press and hold Open/Close Sensor set button for 3 seconds LED will start blinking green 2) Tap Open/Close Sensor set button LED will start double-blinking green 3) For each responder you are adding: a. Adjust responder to desired scene brightness/state b.
Unlinking in Multi-Scene Mode 1) Move Open/Close Sensor magnet away from main case, putting it in open state If Open/Close Sensor was closed, LED will blink once 2) Unlink desired responders from scene 1. See Unlinking an Insteon Responder from Open/Close Sensor.
1) If you are using Open/Close Sensor to control any responders, unlink them from Open/Close Sensor. See Remove Open/Close Sensor as a Controller.
Dimensions Main Case: 3.46" x 1.32" x 0.76" (88mm x 34mm x 19mm) Magnet: 2.28" x 0.55" x 0.43" (58mm x 14mm x 11mm) Weight 3.
Español [Spanish]: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directiva 1999/5/CE. Português [Portuguese]: Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999/5/EC. Italiano [Italian]: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/CE.