Owners Manual (Revisions Prior to 1.9)

Open/Close Sensor Hardware
Reed Switch
Detects whether magnet is within ½ of the main case:
Closed state when magnet is within ½
Opened state when magnet is further than ½
Set Button
Links other Insteon devices (responders)
Controls linked responders (scene 1): Tap to toggle between on and off
External Sensor Terminals
When using an external sensor, Open/Close Sensor is in closed state when
either external sensor terminals or reed switch are closed. In other words,
Open/Close Sensor opens when both external sensor terminals and reed
switch are open. See Advanced External Sensor Use for more information.
Status LED
Indicates:
Change in state (open or close)
Linking/unlinking mode (blinks)
Arrows
Arrows indicate reed switch location inside main case, so magnet should be
installed as close as to them as possible.
Magnet
Included magnet is installed on opposing plane than Open/Close Sensor main
case. It should be less than ½ away from the main case when door/window,
etc. is closed and further than ½ when open.
Installation
Install Open/Close Sensor
1) Remove sensor (larger device) cover by prying up at “open”
2) Install included AA battery (don’t replace cover yet)
3) Peel backing off double-stick tape on back of sensor
4) Mount sensor:
If installing on door, with white set button between door edge and battery, gently press sensor to door frame
approximately 3” from top of door (such that door slightly clears it when closing)
If installing on window, with set button between window and battery, gently press to window frame (such that
window will slightly clears it when closing)
5) Press and hold sensor set button for 5 seconds until LED begins blinking
6) For US installations, press and hold nearest Range Extender (previously called Access Point) set button until it
beeps
a) If sensor LED continues blinking, sensor is not within range, move Range Extender to a closer outlet and
return to step 5
7) Peel backing off double-stick tape on back of magnet case
8) Mount magnet:
If installing on door, mount magnet as near door edge as possible (within ½” of sensor horizontally) and with
one end of magnet aligned with set button and other end of magnet aligned with far end of sensor, gently
press on door
If installing on window:
a) Open window and carefully replace sensor cover (open label on same side as battery)
b) Close window
c) Gently apply magnet to window as close to sensor as possible
d) Open window and carefully remove sensor cover
9) Test by opening and closing door or window
Sensor LED will blink once each time opened or closed
(Antenna not
shown for clarity)
Page 3 of 9 2843-222/2843-422/2843-522 - Rev: 5/6/2015 4:06:13 PM