Owners Manual (Revisions Prior to 1.9)

Unlinking in Multi-Scene Mode
1) Move Open/Close Sensor magnet away from main case, putting it in open state
If Open/Close Sensor was closed, LED will blink once
2) Unlink desired responders from scene 1. See Unlinking an Insteon Responder from Open/Close Sensor.
Responders will no longer respond when Open/Close Sensor is opened or set button is tapped
3) Move Open/Close Sensor magnet close to main case, putting it in closed state
Open/Close Sensor status LED will blink once
4) Unlink desired responders from scene 2
Responders will no longer respond when Open/Close Sensor is closed or set button is tapped
5) Test by opening and closing your door or window
Responders will no longer respond when Open/Close Sensor is opened or closed
Scenes
Devices in a scene can each have different settings. This provides for advanced lighting, audio, etc scene creation.
Software is recommended for scene management.
Insteon scenes are very easy to set up just link more than one responder to the same controller. Then, all Insteon
devices linked in the scene will respond as a group.
Advanced Features
Advanced External Sensor Use
For advanced users, a single Open/Close Sensor can be used to:
Monitor several doors/windows
Monitor several different types of sensors
Monitor external sensors in addition to its internal reed switch
Using Several Sensors
When several sensors (even of different types) are connected to Open/Close Sensor external sensor terminals, keep
in mind that Open/Close Sensor only has two states: opened and closed. So if you have several sensors connected
in the following configurations, note Open/Close Sensor behavior (it is assumed in this example Open/Close Sensor
internal reed switch is not being used).
Several sensors connected in series Open/Close Sensor will show open if any sensors are open and
closed when all sensors are closed
Several sensors connected in parallel Open/Close Sensor will show open when all sensors are open and
closed if any sensors are closed
NOTE: If magnetic door/window contacts are used, there are two types:
Normally open when door/window is closed, sensor will show open. When door/window is open, sensor will
show closed
Normally closed when door/window is closed, sensor will show closed. When door/window is open, sensor
will show open
Using Internal Reed Switch and External Sensors
When Open/Close Sensor external sensors input is used in conjunction with its internal reed switch, Open/Close
Sensor behaves much like several sensors connected in parallel (above), meaning:
Open/Close Sensor will be open when both internal reed switch and external reed switch sensor terminals
show open
Open/Close Sensor will be closed when either internal reed switch or external sensor terminals show closed
Power Restore
Open/Close Sensor stores all of its settings, such as links to other Insteon devices, with non-volatile memory.
Because settings are saved in non-volatile memory, they will not be lost when the battery is removed.
Factory Reset
All settings and scenes will be erased and return to factory default settings.
Page 6 of 9 2843-222/2843-422/2843-522 - Rev: 5/6/2015 4:06:13 PM