DIN Rail Dimmer Owner’s Manual 2452-222 (US) 2452-422 (EU) 2452-522 (AUS/NZ) Page 1 of 19 2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM
About DIN Rail Dimmer ................................................................................................................................................. 3 Installation Preparation ................................................................................................................................................ 3 Identifying the Electrical Wires in Your Home (North America only) ...........................................................................
About DIN Rail Dimmer Tools Needed Slotted screwdriver Wire cutter/stripper Voltage Meter Sense #2 Sense #1 Optional Accessories INSTEON Hub Mini Remote Connected load LED Paddle top (on/brighten) Fuse (US Only) Paddle bottom (off/dim) Set button Neutral Line Installation Preparation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference.
Identify Switch Type Before you install DIN Rail behind a switch, you must determine which type of switch you have—latching (the default setting), single momentary or dual momentary—as each is wired differently. If you are using DIN Rail with a single momentary or dual momentary switch, you will program it for the corresponding switch after installation.
Switch Operation Mode By default, DIN Rail is programmed for a latching switch. If you are installing DIN Rail behind a single momentary or dual momentary switch, you must change DIN Rail’s local-control switch operation to single momentary mode or dual momentary mode.
Local Control Operations DIN Rail’s switch operation mode affects how it responds to commands; so it’s important to properly program DIN Rail for the correct type of switch you are installing. DIN Rail on/off buttons function exactly like the top and bottom of your wall switch. Note: LED will blink red for a few seconds if one or more responders do not acknowledge a message.
3) Press and hold set button until it beeps a third time LED will start blinking green 4) Press and hold set button until it beeps a fourth time LED will start blinking red 5) Slowly tap set button once LED will start double-blinking red 6) Press and hold DIN Rail on/off buttons to dim and brighten load to desired brightness 7) Press and hold set button until it double-beeps LED will stop blinking LED will turn green 8) Test by turning switch off and then back on Load will turn on to new local on-level Loc
2) Press and hold set button until it beeps a second time LED will start blinking red 3) Press and hold set button until it beeps a third time LED will start blinking green 4) Press and hold set button until it beeps a fourth time LED will start blinking red 5) Slowly tap set button three times LED will start double-blinking red 6) Press and hold set button until it double-beeps LED will stop blinking 7) Test by turning off and then back on via the local switch Load will ramp off and back on to resume dim l
Make DIN Rail a Responder Control DIN Rail from another INSTEON device: 1) Press and hold controller button until it beeps Controller LED will start blinking 2) Press and hold DIN Rail paddle top or bottom to adjust load to desired brightness (or off) when scene is activated Connected load will respond appropriately DIN Rail 3) Press and hold DIN Rail set button until it double-beeps Controller (Responder) Controller will double-beep and its LED will stop blinking 4) Test by tapping controller button on and
1) Press and hold controller button until it beeps Controller LED will start blinking green 2) Tap controller set button Controller LED will start double-blinking green 3) Tap DIN Rail on and adjust to desired scene brightness DIN Rail LED will be green 4) Press and hold DIN Rail set button until it double-beeps 5) For each additional scene member: a. Adjust member to desired scene brightness b.
2) Press and hold DIN Rail set button until it beeps a second time DIN Rail LED will start blinking red 3) Tap DIN Rail set button DIN Rail LED will start double-blinking red 4) For each responder you are removing, press and hold responder set button until it double-beeps 5) Tap On, Off or the Set button once to exit Multi-Unlink DIN Rail LED will stop blinking 6) Test by tapping DIN Rail on and off None of the former responders will respond Factory Reset All settings and scenes will be erased and return t
Specifications General Product name DIN Rail Dimmer Brand/manufacturer INSTEON Manufacturer product number UPC Warranty US 2452-222 EU 2452-422 AUS/NZ 2452-522 US 813922012798 EU 813922012804 AUS/NZ 813922012811 2 years, limited INSTEON INSTEON powerline mesh repeater Yes INSTEON RF mesh repeater Yes INSTEON controller Yes INSTEON responder Yes Maximum links/scenes 400 Load brightness levels 32 locally (256 with software) LED Green when load is on, red when load is off.
X10 transmitter Yes X10 receiver Yes X10 status response Supported X10 resume dim Supported (by setting local on-level to zero) X10 minimum transmit level 3.2 Vpp into 5 Ohms X10 minimum receive level 20mV into 5 Ohms X10 messages repeated No Mechanical Mounting 35mm (top hat) DIN Rail Wires NA Max Cable Size 4mm2, 12 AWG (2.72mm Diameter) Min Cable Size 1.
AUS/NZ Hardwired remote control Yes, either latching or momentary switches supported Retains all settings without power Yes, saved in non-volatile EEPROM Standby power consumption < 1 watt Safety approval(s) ETL, CE, C-Tick Certifications FCC 15.107, 15.109, 15.
Troubleshooting Problem Possible Cause Solution Make sure the circuit breaker is turned on The LED on DIN Rail is not turning on at all and won't control my light Check junction box wires to ensure all connections are tight and no bare wires are exposed DIN Rail is not getting power Check the light fixture to ensure all connections are tight and no bare wires are exposed Check fuse to ensure it is not broken.
DIN Rail, it takes a long time for other INSTEON devices it is controlling to respond scene responder that is not powered on If the INSTEON device is still available, remove it from DIN Rail and then re-add it Perform a factory reset The dimming component The load is buzzing when inside DIN Rail "chops" the on or dim power line sine wave to reduce the power The bulb filaments are vibrating.
Phase Bridge Detect Beacon/RF Range Test Dimmer module automatically bridges the electrical phases in your home (via communications with other dual-band devices on the “other phase”). This is only important in 2-phase homes with powerline-only INSTEON products or buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to see if your devices are within communication range. You will need at least one other INSTEON dual-band device installed.
Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S.
liability with respect to this product. For repair or replacement during the warranty period, call INSTEON at 866-243-8022 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to: INSTEON ATTN: Receiving 16542 Millikan Ave.