® INSTEON Door Sensor 2845-x22 Owner’s Manual
Contents Getting Started INSTEON Hidden Door Sensor 4 Device Overview Tools Needed for Installation Test Your Location First Install in a Window Frame Installation Link First 6 Locate the Hole Drill the Hole Test the Fit Using the Spacer INSTEON Links Understanding Linking Linking to the INSTEON Hub Linking to Control Another Device Already Installed Linking Multi-Linking or Making a Scene Unlinking a Device Multi-Unlinking or Removing a Scene Local Programming Local Programming Factory Reset
Getting Started Everything you need to quickly get up and running.
INSTEON Hidden Door Sensor Device Overview Tools Needed for Installation ® Model: 2845-222 Door Sensor ® Model: 2845-222 Door Sensor Contact Plunger Set Button Status LED Power Drill Battery Isolation Tab AAA Battery (Remove before first use) (Included) (Recommended) ® Model: 2845-222 Door Sensor 3/4-inch Auger Drill Bit Spacer Spacer Screw Test Your Location First Test your desired location first.
Installation Unbox and read instructions Test linking in the intended location Link with all devices you wish to control Drill a mounting hole and test fit the sensor Install Door Sensor and secure with a screw Oops. Forgot to link a device? See Already Installed Linking.
Installation Link First 1 As installing Door Sensor obscures its set button, perform any linking now before you install the sensor. Locate the Hole 2 Find a location for Door Sensor in either the hinge-side of the door frame or the hinge-side of the door itself. Higher is better for wireless range but low will still work. X X For linking instructions, turn to Page 9. ? If you skip linking now, you can link later using Five-Tap linking.
Using the Spacer Model: 2845-222 ® Slide the spacer over Door Sensor to increase the thickness of the collar. Fasten with the screw provided. Door Sensor If the gap between your door and door frame is too wide to depress the contact plunger, try using the spacer.
INSTEON Links INSTEON devices can stand alone and function as a local switch or dimmer, but their real power comes when they are connected together to form a control system. Most INSTEON devices can control one another and be the recipient of control. The process of associating multiple INSTEON devices to one another is called Linking.
Understanding Linking Links are One-Way When linking INSTEON devices, the links that are created are one-way. Links Remember a Device’s State The current state of the controlled device is stored in the link: On, off or dimmed. NEW NEW 75% ® A B Switch A will turn Switch B on and off but Switch B cannot turn Switch A on or off. X Controllers INSTEON devices that can turn other devices on or off are called controllers.
Understanding Linking Controller-Only Some devices, like sensors, can only control other devices. Responder-Only Some devices cannot control other devices; these devices only receive INSTEON commands. NEW NEW X X ® Motion Sensor Dimmer Switch The Motion Sensor will turn on the Switch but the switches cannot control the Motion X Sensor. Grouping Devices You may want to group together two devices, for example, in a virtual-three way configuration. For INSTEON, this is called Cross Linking.
Linking to the INSTEON Hub 1 From Rooms, navigate to All Devices. 2 Tap the Add button. All Devices Rooms All Devices Check-In Favorites Back Door Bathroom Bedroom Bathroom Bedroom Hallway Font Door Garage Door Garage Light Kitchen Living Room Outside Motion Sensor Outside Lights 72º 72º Select Door Sensor from the list of devices. 4 When prompted, press and hold the set button on your Door Sensor until the device beeps.
Linking to Control Another Device 2 Adjust your responder to the desired state: On, off, or brightness level if dimming, and then press and hold the set button until the device double-beeps. Model: 2845-222 Door Sensor ® Model: 2845-222 Door Sensor ® On your Door Sensor, press and hold the set button until the device beeps. ® 1 ® Your INSTEON controller will now control your On/Off Module.
Already Installed Linking Link Hidden Door Sensor without removing from your door frame 1 If Your Door Is Already Open If Your Door Is Closed Open your door and press and release Door Sensor’s contact plunger twice. After a pause, Door Sensor will beep. Press and release Door Sensor’s contact plunger twice then hold the contact plunger until Door Sensor beeps. OR ? Once in linking mode, you can open or close the door without exiting linking mode.
Already Installed Linking Link Hidden Door Sensor without removing from your door frame Model: 2845-222 ® Adjust your responder to the desired state: On, off, or brightness level if dimming, and then press and hold the set button until the device double-beeps. Door Sensor 2 ® ® Your INSTEON controller will now control your On/Off Module.
Multi-Linking or Making a Scene Adjust your scene members to their desired state: On, off, or brightness level if dimming. 2 Model: 2845-222 ® On your Door Sensor, press and hold the set button until the device beeps then tap the set button. Door Sensor 1 50% 72% Lamp 1 Lamp 2 30% ON Lamp 3 Appliance A B Tap the set button on your Door Sensor to finish building your scene. ® 4 Model: 2845-222 One at a time, press and hold the set button on each scene member until it double-beeps.
Unlinking a Device Model: 2845-222 Door Sensor ® Model: 2845-222 ® Press and hold the controlled device’s set button until the device double-beeps. Door Sensor 3 Press and hold the set button again until the device beeps . 2 Model: 2845-222 ® On your Door Sensor, press and hold the set button until the device beeps. Door Sensor 1 X ® ® Your Door Sensor will no longer control your INSTEON device.
Multi-Unlinking or Removing a Scene Press and hold the controlled device’s set button until the device double-beeps. ® 4 Model: 2845-222 Model: 2845-222 Door Sensor ® Press and hold the set button again until the device beeps. Model: 2845-222 Tap the set button. 2 Door Sensor 3 ® On your Door Sensor, press and hold the set button until the device beeps.
Multi-Unlinking or Removing a Scene Tap the set button on your Door Sensor to exit Multi-Unlinking mode. ® Model: 2845-222 Door Sensor ® X Model: 2845-222 ® ® Door Sensor 5 ® Your Door Sensor will no longer control your INSTEON responders.
Local Programming Encompassing all on-device programming options, use the local programming to set local properties. properties and For factory the bestreset. experience, For the use best experience, software for use managing software device for managing properties. device properties.
NEW Local Programming About the Flow Chart Local Programming is a visual representation of the device’s settings. Many device features can be configured using the flow chart. Some devices have more options than others but the programming wheel presents even the most complicated devices with a straightforward, navigable path.
Local Programming ® Model: 2845-222 Door Sensor Linking Mode Press Unlinking Mode Press Exit Tap Tap Multi-Linking Mode Press Exit MultiUnlinking Mode Press Exit Tap Tap Exit Exit 21
Factory Reset A factory reset will erase all links stored in the device’s database as well as any customized properties.
Factory Reset 1 Remove Door Rensor from the door frame and take out the sensor’s battery. 2 Press and hold the set button while reinstalling the battery. ® Door Sensor Model: 2845-222 ® Door Sensor ® Door Sensor ® Model: 2845-222 Model: 2845-222 Continue to hold the set button until the long beep stops. Let go and Door Sensor will emit a double-beep. Door Sensor 3 Model: 2845-222 LONG ® Door Sensor Model: 2845-222 Your Door Sensor has been restored to factory settings.
Software-Only Features Most INSTEON devices contain features that can only be enabled, disabled or modified using INSTEON control software such as HouseLinc and an INSTEON PowerLine Modem.
Software-Only Features Enable Group 1 & 2 Broadcast When enabled, Door Sensor will send a separate On for opening and for closing. Useful if you want a device to turn on when the door closes, like a bathroom fan. Prevents changing any settings using the set button or tap-and-hold programming.
Software-Only Features Low Battery Warning Enable or disable a low battery broadcast that can trigger events with software.
Appendix Everything else you might need to know about your INSTEON product.
INSTEON Glossary Controller Responder Blinking The INSTEON transmitter The INSTEON receiver LED turning on and off repeatedly Dual-Band An INSTEON device that can send and receive both INSTEON powerline signals and INSTEON radio frequency signals Ramp Rate The speed at which the load fades on or off On-Level The preset brightness level a device will return to when turned on INSTEON A dual-band, mesh networking technology developed by Smarthome/INSTEON.
Specifications General Available Colors White Brand INSTEON FCC ID SPB28452 Industry Canada 5202A-28452 Product Number. 2845-222 US 2845-422 EU 2845-522 AUS/NZ Patent UPC Warranty Protected under US and Freign Patents (see www.insteon.
Specifications Maximum Scene Memberships 1 Multi-Link Support Yes Multi-Unlink Support Yes Phase Detect Beacon No Radio Frequency Radio Frequency Range 915 MHz US 869.85 MHz EU 921 MHz AUS/NZ 150 feet Scene Commands Supported as Controller On Scene Commands Supported as Responder None Software Configurable Off Yes Mechanical Switch Type Momentary mechanical switch Dimensions 0.75” diameter, 3.4” length 15.
Specifications Electrical Battery Type AAA Battery Life 6 months Certification N/A, Battery-powered device Power Consumption Supply Voltage 60μA 1.
Troubleshooting Door Sensor won’t link to other INSTEON Devices Your Door Sensor may be out of range of a dual-band INSTEON device or your network may be powerline-only. Try this: • If your INSTEON network lacks any dual-band devices, add a Range Extender or other dual-band INSTEON device near your Door Sensor to bridge the INSTEON RF and powerline networks. • Door Sensor must be placed within 100’ of a dual-band device. Radio interference and building construction may reduce range.
Certifications and Warnings This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
Certifications and Warnings It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
Product Warranty Limited Warranty Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect.