In-LineLinc™ Dimmer INSTEON® In-LineLinc Dimmer, Dual-Band Owner’s Manual (#2475DA1) Page 1 of 14 2475DA1 - Rev: 1/21/2014 7:52 AM
In-LineLinc Dimmer Dual-Band.................................................................................................................. 3 Features and Benefits................................................................................................................................. 3 What’s in the Box? ..................................................................................................................................... 3 Installation ..............................................
In-LineLinc Dimmer Dual-Band Congratulations on your purchase of the elegant, high-quality In-LineLinc Dimmer Dual-Band. In-LineLinc Dimmer installs in-line to provide INSTEON control of individual dimmable lighting fixtures. Additionally, In-LineLinc Dimmer eliminates the need for a conventional light switch, reducing the “switch sprawl” common to automation projects. You can also use In-LineLinc Dimmer for INSTEON signal repeating and phase bridging (like an Access Point, #2443).
Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. In-LineLinc Dimmer Dual-Band is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only.
Installing In-LineLinc Dimmer 1) At electrical panel, turn off circuit breaker(s) and/or remove fuse(s) feeding wall box. Verify the power is off. 2) Remove the fixture’s wallplate, unscrew the fixture and pull it out from the junction box. 3) Disconnect the wires from the fixture and In-LineLinc Wire Wall Box Wires ensure that you have ½” of bare wire on Ground 1 the ends. Bare copper (commonly bare green wire or 4) After ensuring wires are not touching, turn green screw) breaker(s) back on.
Using In-LineLinc Dimmer LEDs LED Meaning Solid green Load is on (at any dim level) Solid red Load is off Blinking green Unit is in linking mode Blinking red Unit is in unlinking mode Fast blinking red and optional blink-on-traffic is turned on Dimmer is off and INSTEON traffic received Fast blinking green and optional Dimmer is on and INSTEON traffic received blink-on-traffic is turned on Using the ON and OFF Buttons The small button switches allows you to test the load and functions prior to
Beeper Behavior In-LineLinc Dimmer features a built-in beeper which aids in programming and can also be used as an indicator via compatible software controllers.
Dimmer to bridge the building’s electrical phases, use the following procedure to activate phase bridging detection mode: 1) Start phase bridging detection mode by tapping In-LineLinc Dimmer’s Set button four times quickly. In-LineLinc Dimmer will begin beeping and setup LED will be solid green. 2) Check the LED behavior of the “other” dual-band devices. a) If it is blinking green, it is within range and not on the same electrical phase. Go to step 3.
Local Ramp Rate The local ramp rate is the time it takes for the light(s) physically wired to In-LineLinc Dimmer to brighten from off to 100% brightness and vice versa. The default ramp rate is 0.5 seconds, but it is adjustable from 0.1 seconds to 9 seconds locally or up to 8 minutes using software such as HouseLinc. Ramp rate is determined using the brightness level of the load. Refer to the chart below to determine the ramping speed based on the load brightness.
Specifications General Product name In-LineLinc Dimmer Dual-Band – INSTEON Remote Control In-Line Dimmer (Dual-Band) Brand INSTEON Manufacturer product number 2475DA1 UPC 813922012361 FCC ID SBP2475DA1 Patent number 7,345,998; protected under U.S. and foreign patents (see www.insteon.com ) Warranty 2 years, limited INSTEON INSTEON I.D.
INSTEON device category 0x01 INSTEON device subcategory 0x32 Mechanical Mounting Mounts inside standard electrical box in the ceiling or in the wall Colors: White – Neutral 18-gauge Black – Hot 16-gauge Wires Red – Load 16-gauge Copper – Earth ground 14-gauge Set button 1 Beeper Yes LED Dual-color green and red Dimensions 2.75" H x 1.75" W x 0.88" D Weight 120 grams / 0.
Maximum load 400 Watts Load type(s) Wired-in incandescent lighting Retains all settings without power Yes, all saved in Non-volatile EEPROM Standby power consumption < 1 watt Safety approved ETL (Intertek Testing Services) Certifications FCC, IC Canada Page 12 of 14 2475DA1 - Rev: 1/21/2014 7:52 AM
Troubleshooting Problem In-LineLinc Dimmer won’t control the load and the Status LED is not turning on. In-LineLinc Dimmer won’t add to a scene or respond to a controller. Possible Cause Solution Make sure the circuit breaker is turned on. In-LineLinc Dimmer may not be getting power. Check the junction box wires to ensure all connections are tight and no bare wires are exposed. The controller might have been reset without removing In-LineLinc Dimmer from a scene.
Certification and Warranty Certification This product has been thoroughly tested by Intertek ETL, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S.