Quick Start Owner manual

Installation
1) If you plan to configure In-LineLinc using INSTEON-compatible software, write down the INSTEON I.D.
and the location of the fixture you’ll be controlling (e.g., 01.F7.G5, Mike’s bedroom light).
2) At the circuit breaker or fuse panel, disable the circuit supplying power to the fixture.
3) Remove the wallplate from the fixture you are replacing. Unscrew the fixture itself and pull it out from the
junction box.
4) Disconnect the wires from the fixture you will be controlling and ensure that you have ½” of bare wire on
the ends.
5) To correctly identify the Line, Load, Neutral and Ground wires, enable power to the fixture from the
circuit breaker or fuse panel, use a line voltage meter, and then turn the breaker off again.
6) Wiring – Reference either the diagram for “Typical Wiring (without Sense)” or “Wiring with Sense” on the
next page to properly connect In-LineLinc to the fixture.
7) Prior to reinstalling the fixture, enable power to the fixture from the circuit breaker or fuse panel.
8) Use the On/Off buttons to test that the module is working and controlling the load.
9) Follow the linking instructions on the next page to link your device to In-LineLinc.
a. Typical wiring (without Sense) – “Linking In-LineLinc as an INSTEON Responder”
b. Wiring with Sense – “Linking In-LineLinc as an INSTEON Controller”
10) Gently place In-LineLinc into the junction box, making sure that nothing could accidentally press any of
the buttons on its face.
11) Reinstall the fixture.
Quick-Start Guide
In-LineLinc
TM
Relay - INSTEON
®
On/Off Module
(non-dimming) with Sense
Model: 2475S2 – 15 Amps, Rev 5.3+
Preparation
Installation should be performed only by a qualified
electrician or a homeowner who is familiar and
comfortable with electrical circuitry. If you have any
questions regarding installation, we suggest consulting
an electrician. If you have any questions regarding
setup, contact the INSTEON Support Line.
Tools Needed
Phillips screwdriver
Status LED
Set button
Off button
On button
Introduction
Your new INSTEON In-LineLinc On/Off Module with
Sense wires in-line for ceiling fans and fluorescent
lighting circuits without wall switches. Independent load
wires allow you to control devices of any voltage up to
120V. Or, use the Sense wire to control linked
INSTEON devices based on the state of the load
attached to In-LineLinc.
Wire
cutter/stripper
Voltage tester to identify wires inside the junction box
Probe that is non-conductive to press the Set button (e.g., pencil)
Limited Warranty – INSTEON warrants to original consumer of this product for a period of 2 years from date of purchase,
this product will be free from defects in material and workmanship and will perform in substantial conformity with its Owner's
Manual. Warranty shall not apply to defects caused by misuse or neglect.
Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012
INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
Page 1
Rev. 03-
of 2
15-2012

Summary of content (2 pages)