Open/Close Sensor Owner’s Manual 2843-222 (US) 2843-422 (EU) 2843-522 (AUS/NZ) Hardware Revision 1.
About Open/Close Sensor ............................................................................................................................................ 2 Open/Close Sensor Hardware ..................................................................................................................................... 3 Installation .....................................................................................................................................................................
Open/Close Sensor Hardware Reed Switch Detects whether magnet is within ½” of the main case: • Closed state when magnet is within ½” • Opened state when magnet is further than ½” Jumper When jumper is installed (default), Open/Close Sensor will send an INSTEON “on” command when it opens and an “off” command when it closes. When jumper is uninstalled (as in Multi-Scene Mode), Open/Close Sensor will activate scene 1 when it opens and activate scene 2 when it closes.
• If installing on door, mount magnet as near door edge as possible (within ½” of sensor horizontally) and with one end of magnet aligned with set button and other end of magnet aligned with far end of sensor, gently press on door • If installing on window: a) Open window and carefully replace sensor cover (open label on same side as battery) b) Close window c) Gently apply magnet to window as close to sensor as possible d) Open window and carefully remove sensor cover 9) Test by opening and closing door o
Make Open/Close Sensor a Controller Use Open/Close Sensor to control other INSTEON devices: 1) If using default mode, ensure Open/Close Sensor jumper is installed. If using multi-scene mode, jumper should be uninstalled (or removed). NOTE: When changing jumper setting, battery will need to be removed and then reinstalled for new jumper setting to take effect.
Linking in Multi-Scene Mode 1) Open Open/Close Sensor cover and ensure jumper is uninstalled (or removed). When uninstalling jumper, battery needs to be removed and then reinstalled for new jumper setting to take effect 2) Move Open/Close Sensor magnet away from main case, putting it in open state If Open/Close Sensor was closed, LED will blink once 3) Link desired responders for when Open/Close Sensor opens (scene 1). See Make Open/Close Sensor a Controller.
• Normally open – when door/window is closed, sensor will show open. When door/window is open, sensor will show closed • Normally closed – when door/window is closed, sensor will show closed.
INSTEON Addresses 1 hard-coded out of 16,777,216 possible INSTEON controller Yes INSTEON responder No Maximum links/scenes 30 Software configurable Yes RF range Up to 150 feet (50 meters) open air* *Range may vary due to local interference INSTEON device category 0x10 (all frequencies) INSTEON device subcategory US 0x02 EU 0x06 AUS/NZ 0x07 Mechanical Case color White Set button Yes Dimensions Main Case: 3.46" x 1.32" x 0.76" (88mm x 34mm x 19mm) Magnet: 2.28" x 0.55" x 0.
WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.