Technical Specifications

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2013 Page 1 of 1
1000
ICC-ES Evaluation Report
ESR-3468
Reissued May 1, 2013
This report is subject to renewal May 1, 2014.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council
®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 25 00—Water-Resistive Barriers/Weather
Barriers
REPORT HOLDER:
INSULATION SOLUTIONS INC.
401 TRUCK HAVEN ROAD
EAST PEORIA, ILLINOIS 61611
(309) 698-0062
www.insulationsolutions.com
EVALUATION SUBJECT:
WRAPTOR WEATHER RESISTIVE BARRIER
1.0 EVALUATION SCOPE
Compliance with the following codes:
2009 International Building Code
®
(IBC)
2009 International Residential Code
®
(IRC)
Property evaluated:
Water resistance
2.0 USES
Wraptor Weather Resistive Barrier is used as a water-
resistive barrier on the exterior side of exterior walls of
buildings of Type V-B construction, and of non-fire-
resistance-rated construction permitted under the IRC. The
Wraptor Weather Resistive Barrier is an alternative to the
water-resistive barrier specified in IBC Section 1404.2 and
IRC Section R703.2. The product is considered equivalent
to 60-minute Grade D paper as described in IBC Section
2510.6 and IRC Section R703.6.3.
3.0 DESCRIPTION
Wraptor Weather Resistive Barrier consists of a perforated,
microporous, woven polyolefin fabric, with an additional
polyolefin coating on the exterior side. The product is 0.004
inch thick (0.11mm) and is available in rolls with widths
ranging from 3 feet to 10 feet (0.92 m to 3.05 m) and in
lengths ranging from 30 feet to 195 feet (9.1 m to 59.4 m).
4.0 INSTALLATION
The published installation instructions and this report must
be strictly adhered to. If requested by the code official, a
copy of this report must be available at the jobsite during
installation. In the event of a conflict between this report
and the published installation instructions, this report
governs.
Wraptor Weather Resistive Barrier must be installed after
wall framing is completed and before windows and doors
are installed. The roll must be placed a minimum of
6 inches (152 mm) from the starting corner and fastened to
the sheathing with corrosion-resistant nails having
minimum 1-inch-diameter (25.4 mm) plastic washer heads
or cap heads, spaced at a maximum of 16 inches
(406 mm) on center, or corrosion-resistant staples with
minimum 1-inch (25.4 mm) crowns, spaced a maximum of
12 inches (305 mm) on center; and must then be unrolled
around the building and fastened with nails spaced at a
maximum of 16 inches (406 mm) on center or staples
spaced a maximum of 12 inches (305 mm) on center. The
printed side of the product must be installed facing the
outside. A minimum of 8 inches (203 mm) of overlap must
be provided for vertical seams and 4 inches (102 mm) for
horizontal seams, except where the manufacturer’s
published installation instructions specify a greater overlap.
When used over wood-based sheathing in exterior plaster
applications, the product must be applied over the
sheathing in accordance with IBC Section 2510.6 or IRC
Section R703.6.3, using two layers of the product or using
one layer together with an intervening, substantially non-
water-absorbing layer or drainage space. For cementitious
coatings or exterior insulation and finish systems,
application must be in accordance with the evaluation
report on the exterior coating.
5.0 CONDITIONS OF USE
The Wraptor Weather Resistive Barrier described in this
report complies with, or is a suitable alternative to what is
specified in, those codes listed in Section 1.0 of this report,
subject to the following conditions:
5.1 The published installation instructions and this report
must be strictly adhered to. In the event of a conflict
between this report and the published installation
instructions, this report governs.
5.2 The product must be covered in accordance with the
published installation instructions with an approved
exterior wall covering complying with the applicable
code.
6.0 EVIDENCE SUBMITTED
Data in accordance with ICC-ES Acceptance Criteria for
Water-resistive Barriers (AC38), dated June 2011.
7.0 IDENTIFICATION
The Wraptor Weather Resistive Barrier is identified by a
label on the container, and by printing at regular intervals
on the product, that includes the report holder’s name
(Insulation Solutions Inc.), the manufacturing location, the
product name (Wraptor Weather Resistive Barrier), and the
evaluation report number (ESR-3468).