Operating Manual INSYS Modem 56k File E239995 Juni 05
Copyright © March June 05 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited. All rights on this documentation and the devices are with INSYS MICROELECTRONICS GmbH Regensburg. Restrictions of guarantee This handbook contains a concise description. The compilation of the text has been made with the utmost care. Despite all efforts, there may be deviations compared with the actual functions. No guarantee can therefore be given for the accuracy of the contents.
INSYS Modem 56k UL 1 SCOPE OF DELIVERY ................................................... 4 2 GENERAL .................................................................... 4 3 INITIAL OPERATION.................................................... 5 3.1 IMPORTANT SAFETY INSTRUCTIONS ! ................................... 5 3.2 INSTALLATION OVERVIEW ........................................................... 5 3.3 INSTALLATION STEPS ..................................................................
Content INSYS Modem 56k UL 4.6 ALARM INPUT ......................................................................... 13 4.6.1 4.6.2 Alarm Trigger.................................................................................... 14 Alarm Actions ................................................................................... 15 4.6.2.1 4.6.2.2 4.6.2.3 4.6.2.4 4.6.2.5 Simple alarm ........................................................................................................
INSYS Modem 56k UL 5.2.8 Digital Inputs and Outputs............................................................... 26 5.2.8.1 5.2.8.2 Alarm input: .........................................................................................................26 Control output: ....................................................................................................26 5.3 TRANSMISSION STANDARDS/PROTOCOLS .................................... 26 5.4 FIRMWARE ........................................
Sope Of Delivery 1 INSYS Modem 56k UL Scope Of Delivery Please check that the box contains all of the following parts before installation and operation: • 1 INSYS Modem 144 or INSYS Modem 336 or INSYS Modem 56K • 1 TAE cable • 1 RS 232 cable (9 pin plug to 9 pin jack) • 1 operating manual If any part is missing, please contact your supplier. Please also inspect the modem for transport damage and in the event of damage, consult your supplier. Please keep packaging for future dispatch or storage.
INSYS Modem 56k UL 3 Initial Operation Initial Operation 3.1 IMPORTANT SAFETY INSTRUCTIONS ! When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm.
Initial Operation 3.3 Installation Steps 1. 2. Mounting on DIN rail: simply clip on Power supply: a) Connect earth cable to GND b) Connect power supply cable to 10..60 VDC Note: Maximum ratings at pins 2 and 3 must not be exceeded! c) Connect to power supply The power LED lights up on successful installation. INSYS Modem 56k UL 1 1 2 2 GND X1 3 3 10...
INSYS Modem 56k UL 4 Configiration Configuration 4.1 Configuration Software HSComm INSYS Modem is configured by AT commands from a terminal program or PLC. All basic functions of INSYS Modem can be controlled by the configuration software HSComm without any knowledge about single commands and parameters. The description of settings within HSComm is followed by a list of corresponding AT commands. A terminal window within HSComm allows direct command input when required.
Configuration INSYS Modem 56k UL 4.1.2 AT Commands For Settings Command Description AT&F load factory settings AT&V display settings AT&W save user settings ATZ software reset A comprehensive description of all AT commands and parameters is available in the addendum „command overview“. 4.
INSYS Modem 56k UL Configiration 4.2.1 PC Settings Within HSComm the serial line setting are configured by the menu interface. The actual settings are displayed in the status line of the program window. Note: Serial setting has to be configured in any device (PC or PLC) connected to the INSYS Modem. 4.2.2 INSYS Modem Settings Serial line settings of the INSYS Modem are accessed by the menu Configure Æ Modem.
Configuration INSYS Modem 56k UL Data transmission on the remote line does not reset the counter. Idle connection control of the remote modem must be switched off for remote control therefore. Idle connection control is configured by AT command only. 4.2.
INSYS Modem 56k UL Configiration 4.3.2 International Settings INSYS Modem 56k can be adjusted to the line requirements of 87 countries worldwide by a configuration command. The country codes for the firmware versions “standard countries” and “further countries” are listed in chapter 8. Some countries do not require a separate adaptation but are using the standards “TBR21 (Europe)” or “ITU/Taiwan”.
Configuration INSYS Modem 56k UL Command Description ATP Select pulse dialing ATT Select tone dialing AT%Q Display phone connection quality ATS0 auto answer AT+VCID set caller ID (INSYS Modem 56k only) AT+VRID last received caller ID (INSYS Modem 56k only) AT\V connect messages ATX Extended result reporting, dial tone detection AT%L Display level of received signal AT&Z Store phone numbers A comprehensive description of all AT commands and parameters is available in the addendum „com
INSYS Modem 56k UL Configiration 4.4.
Configuration INSYS Modem 56k UL 4.6.1 Alarm Trigger The alarm inputs are on HIGH potential provided by internal pull-up resistors as long as it is open. The alarm is activated by a simple connection to the ground potential. The alarm input is configured by the HSComm menu Configure Æ Alarm functions: • With alarm input active a simple alarm is triggered as soon as INPUT1 is set to ground potential for 4 seconds.
INSYS Modem 56k UL Configiration 4.6.2 Alarm Actions SMS transmission from the analog telephone network is routed by special gateway numbers of the network providers. These Service Center Numbers and the protocol (PET or UCP) are preconfigured for German GSM networks. 4.6.2.1 Simple alarm Alarm notifications consist of an alarm text of a maximum of 160 characters. The notification is transmitted to a modem over data connection or to mobile phone by SMS. 4.6.2.
Configuration INSYS Modem 56k UL 4.6.3 AT Commands For Alarm Actions Command Description AT%A alarm triggering AT*I manual request of the alarm input AT*M protocol for alarm messages AT*V alarm text AT&Z store telephone numbers (mobile, service center, fax) ATS13 number of dialing attempts A comprehensive description of all AT commands and parameters is available in the addendum „command overview“. 4.
INSYS Modem 56k UL Configiration 4.8 Remote Configuration To change into remote configuration mode a data connection must exist between the modems. A specific protocol is not necessary, however it is recommended to use an error corrected connection to avoid transmission errors of critical commands. The local modem does not require any remote configuration functionality. Remote configuration is imitated by the following escape sequence (e.g.
Configuration INSYS Modem 56k UL 4.9 Voice Mode and DTMF Transmission The voice mode of the modem allows • to digitize telephone audio data and to transmit them over the serial line • to play back digitized audio data to the telephone line • to transmit and receive control signals as DTMF 4.9.1 DTMF Sounds Keyboards of fixed network and mobile telephones produce DTMF sounds for the characters (0..9, A..D, *, #) as a combination of two frequencies which do not occur in the human voice.
INSYS Modem 56k UL Configiration The INSYS Modem switches to data mode if it receives the call signal for a data connection from a modem. Acoustic Signals Description short deep sound – short break – short high sound OK ready, command executed, PIN ok long deep sound ERROR invalid command, wrong PIN LOW alarm input active HIGH alarm input not active long high sound 4.9.
Configuration INSYS Modem 56k UL 4.10.1 Upload Procedure 1. Upload is initiated by the AT command AT** - the modem replies „Download initiated“. 2. ASCII upload of the flash loader HS_LADER.S37. The transmission process is displayed by dots in some terminal programs. Upon termination the message „Download Flashcode“ is displayed. 3. ASCII upload of the firmware code (file xxxxxxxx.S37). The transmission process is displayed by dots in some terminal programs.
INSYS Modem 56k UL 5 Command Overview Technical Data All data at nominal input, full load and 25°C ambient temperature. Stresses listed under „Maximun Ring“ (one at time) may be applied to devices without resulting in permanent damage. The operation of the equipment for extended periods may affect device reliabillity. Limiting value tolerance are subject to usal flucation margins. 5.1 General 5.1.
Command Overview INSYS Modem 56k UL 5.2 Interfaces And Display Elements front view 5.2.1 Display Elements The INSYS Modem 56K 4.0 provides four LEDs for status indication.
INSYS Modem 56k UL Command Overview Bottom side terminal: Terminal 11 OUT1NC Output 1 – normally closed 12 OUT1 Output 1 OUT 1-NO 13 OUT1NO Output 1 – normally open OUT 2-NC 14 OUT2NC Output 2 – normally closed 15 OUT2 Output 2 16 OUT2NO Output 2 – normally open 17 b2 Through phone line 18 b1 Phone line 19 a1 Phone line 20 a2 Through phone line OUT 1-NC 12 12 OUT 1 13 13 14 14 15 15 OUT 2 16 16 OUT 2-NO 17 17 b2 18 18 b1 19 19 20 20 a1 a2 RX+ Ethern
Command Overview INSYS Modem 56k UL 5.2.4 Reset Modem reset can be triggered by an external unit over the screw terminal Reset. A low potential has to be applied for a minimum of 3 seconds. Modem reset can also be triggered by the reset key on the front panel. The key has to be pushed for a minimum of 3 seconds. 5.2.5 Serial Interface Layout of the 9 pin D-Sub jack Description of the signals at the 9 pin D-SUB jack of the DCE: 9 pin D-SUB DCE pin no.
INSYS Modem 56k UL Command Overview 5.2.7 Phone Interface RJ 12 plug with nose downward E W 8 7 6 5 4 3 2 1 b2 b1 a2 a1 TAE-Stecker von unten 12345678 RJ 12 plug front RJ45 Stecker front RJ 12 and RJ 45 Pin RJ12 plug Name Pin RJ45 socket Name Pin Name 1 NC 4 a1 7 NC 2 NC 5 b1 8 NC 3 a2 6 b2 a1 and b1 are the incoming phone lines (e.g. outside line or private branch exchange). a2 and b2 are used to connect a phone in series.
Command Overview INSYS Modem 56k UL 5.2.8 Digital Inputs and Outputs 5.2.8.1 Alarm input: LOW 0 .. 1 V HIGH 4 .. 12 V current from LOW to internal +5 V voltage: typ. 0.5 mA 5.2.8.2 Control output: SPDT (single pole double throw) switches by galvanic insulated relays maximum voltage: 30 V (DC) / 30 V (AC) maximum current: 1 A (DC) / 0.5 A (AC) 5.3 Transmission Standards/Protocols Bps indicates the transmitted bits per second. Full duplex means that the transmission takes place into both directions.
INSYS Modem 56k UL Command Overview 5.4 Firmware Checksum Date Mai 2004 Standard Countries Extended Countries F205 9F6E Description supported countries in the firmware versions for standard countries and extended country group see chap. 8 5.5 Approvals The INSYS Modem 144/336/56K bears the CE symbol of conformity.
Command Overview 6 INSYS Modem 56k UL Command Overview 6.1 AT Command AND S-Register Overview A comprehensive description of all AT commands and parameters is available in the addendum „command overview“ from INSYS Microelectronics GmbH , Waffnergasse 8, 93057 Regensburg, Germany Tel +49 941 560061, Fax +49 941 563471, Email: insys@insys-tec.de 6.2 Syntax Of The Standard AT Commands Modem guideline V.25 ter is applicable as regards the time sequence of interface commands.
INSYS Modem 56k UL Command Overview 6.3 Messages Returned For Normal Data Communication Response Code Type Meaning OK 0 final Command executed, no errors CONNECT 1 intermediate Connection set up, if parameter setting X=0 intermediate Connection set up, if parameter setting X>0 CONNECT [] : e.g.: ´ cnx 9600´. Data transfer rate is 9600 Bit/sec. then.
Command Overview Register Function S13* Number of dialing attempts for alarm S14* General settings S15* Data Transmit Controller DTC S17* Remote initial character S21* Settings for V24 S22* Settings S24* Time until changing to sleep mode S25 Units Range Default 1-12 3 138 1s 0-255 0 0-127 42 116 75h (117) s 0-255 0 Time for DTR signal 0.01 s 0-255 5 S26 Time between RTS/CTS 0.
INSYS Modem 56k UL 7 Operation with PLC Operation With PLCs The INSYS Modem 144/336/56K has been tested for the most common PLC systems on the market. The documentation of the settings required for the respective PLC (Application Note) can be requested at INSYS (email: insys@insys-tec.de) Installation by HSComm The configuration software HSComm provides recommended settings for the modems connected to the PLC of to the PC in the central office.
Country Codes 8 INSYS Modem 56k UL Country Codes Adjust the modem to local requirements using the command AT+CGI= All other settings should be carried out after the country code has been selected, because some factory settings depend on these country settings. INSYS Modem 56k 4.
INSYS Modem 56k UL Country Codes INSYS Modem 56k 4.
Country Codes INSYS Modem 56k UL INSYS Modem 56k 4.