6 LEVELING AND CALIBRATION
58
Figure 6. 2 Method to read XY calibration scale
Note: The offset 1 denotes one scale, and the actual offset should be 0.05mm.
If after the reading of printed scale, the center line of printed scale range on horizontal or vertical direction
have large deviation and other scales are difficult to be coincided, this indicates that the XY deviations
have exceeded the measurable range (maximum scale range 15, i.e. 0.75mm). Take following steps:
(1) Firstly, observe the position of the center line of right nozzle model relative to the centerline of left
nozzle model, to determine the deviation direction "-" / "+";
(2) Set the offset value as the maximum value, and click "OK" button;
(3) Carry out XY calibration again, and print the test model, until the confirmed deviation value is
read.