Owner's Manual

128
Zone 2—Continued
The 12V triggers A, B, and C can be used to turn on 12V
trigger-capable components automatically when they are
selected as the input source. The triggers can be set so
that they activate when a connected component is
selected as the input source for the main room, Zone 2 or
any combination of rooms.
When triggered, the output from a 12V TRIGGER OUT
goes high (+12 volts and 125 milliamperes max. at
TRIGGER OUT A; +12 volts and 25 milliamperes max.
at TRIGGER OUT B and C).
Hookup
Use a miniplug cable to connect the AV controller’s
12V TRIGGER OUT A, B, or C jack to the 12 V trig-
ger input on a connected component.
When several components are turned on simultaneously
by using triggers A, B, and C, depending on the type of
components, a large amount of current may be drawn
momentarily. To prevent this, you can delay trigger sig-
nals A, B, and C individually. Another application for
trigger delay is eliminating the “thump” noise that’s
sometimes heard when a source component is turned on.
Delaying the trigger signal for your power amplifier so
that it’s the last component to be turned on will accom-
plish this.
Using the 12V Triggers
1
Press the [Receiver] button, fol-
lowed by the [Setup] button.
The main menu appears onscreen.
2
Use the Up and Down [q]/[w] but-
tons to select “6. Miscella-
neous”, and then press [Enter].
The Miscellaneous menu appears.
3
Use the Up and Down [q]/[w] but-
tons to select “12V Trigger A, B,
or C Setup”, and then press
[Enter].
The 12V Trigger A, B, or C Setup
screen appears.
4
Use the Up and Down [q]/[w] but-
tons to select “Delay”, and use
the Left and Right [e]/[r] but-
tons to select:
0sec (Trigger A: default),
1sec (Trigger B: default),
2sec (Trigger C: default),
or 3sec.
When 0 sec is selected, the trigger sig-
nal is output as soon as the input source
is changed.
5
Use the Up and Down [q]/[w] but-
tons to select an input source,
and use the Left and Right [e]/
[r] buttons to select an option.
Off: No trigger signal is output.
A 12-volt trigger signal is output when
the connected component is selected as
the source for:
Main: Main room.
Zone2: Zone 2.
Main/Zone2:
Main room or Zone 2.
Note:
By default, all input sources on the
“12V Trigger A Setup” menu are set to
“Main”, those on the “12V Trigger B
Setup” menu are set to “Main/Zone2”,
and those on the “12V Trigger C Setup”
menu are set to “Zone2”.
6
When you’ve finished, press the
[Setup] button.
The setup menu closes.
6–3. 12V Trigger A Setup
Delay
DVD/BD
VCR/DVR
CBL/SAT
GAME
AUX
0sec
Main
Main
Main
Main
Main