Setting Item Default Value Setting Details
Network Standby On
When this function is set to "On", the network
function works even in standby state, and you can
turn on the power of the unit via network using an
application such as Integra Control Pro that can
control this unit.
When this function is set to "On", the power
consumption in standby state increases,
however, the increase in power consumption is
minimized by automatically entering the Hybrid
Standby mode where only the essential circuits
operate. Note that even if this function is set to
"Off", when any of the HDMI CEC (
p170),
HDMI Standby Through (
p170), USB Power
Out at Standby (
p174) and Bluetooth
Wakeup ( p175) functions is enabled, this
function will be in "On" state regardless of the
setting.
When connection to the network is lost, "Network
Standby" may be disabled to reduce power
consumption. In such a case, turn the unit on by
using the power button on the remote controller
or main unit.
Bluetooth Wakeup Off
This function wakes up the unit on standby by
connecting a BLUETOOTH-enabled device.
"On": When this function is used
"Off": When this function is not used
When this function is set to "On", the power
consumption in standby state increases,
however, the increase in power consumption is
minimized by automatically entering the Hybird
Standby mode where only the essential circuits
operate.
This setting is xed to "Off" if "Bluetooth" - "Auto
Input Change" is set to "Off".
Wait for a while if "Network Standby" and "Bluetooth Wakeup" cannot be selected. It can
be selected when the network function is activated.
5. 12V Trigger A
Set when outputting the control signal (maximum 12 V/100 mA) through the 12V
TRIGGER OUT A jack. Different settings can be set for each input selector. You
can enable power link operation when you connect the unit and the external
devices equipped with 12V trigger input jack.
Setting Item Default Value Setting Details
Delay 0 sec Set after how many seconds the 12V trigger output
will occur in response to the unit's operation. As
some devices cause a large current when they turn
on, delay the output if such devices are connected.
Select a value between "0 sec" to "3 sec".
BD/DVD Main Set the 12V trigger output setting to each input.
"Off": No output
"Main": Output when "BD/DVD" is selected as input
for main room.
"Zone 2": Output when "BD/DVD" is selected as
input for ZONE2.
"Main/Zone 2": Output when "BD/DVD" is selected
as input for main room or ZONE2.
"Zone 3": Output when "BD/DVD" is selected as
input for ZONE3.
"Main/Zone 3": Output when "BD/DVD" is selected
as input for main room or ZONE3.
"Zone 2/Zone 3": Output when "BD/DVD" is
selected as input for ZONE2 or ZONE3.
"Main/Zone 2/Zone 3": Output when "BD/DVD"
is selected as input for main room, ZONE2 or