Keypad KEY-5.
Precautions 1. 2. 3. 4. 5. 6. 7. 8. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Never expose the unit to moisture. Suitable only for use Indoors. Only connect specified supply voltages. 9. Connect only to the specified terminals. for compliance could void the user’s authority to operate the equipment.
Table of Contents Precautions ..................................... 2 Introduction...................................... 3 Features .......................................... 4 Part Names and Function................ 5 Installation ....................................... 8 System Wiring ................................. 9 Manual Programming .................... 11 Troubleshooting............................. 16 Specifications ................................ 18 Thank you for purchasing an Integra KEY-5.
Features • • • • • • • • • • • • • • • • • • 4 Amplifier dedicated keys: Standby, Volume Up/Down and 6 Source select keys. 32 Source select key-caps providing a selection of Source select key labels. 6 Banks of 16 Source Control keys. Integra Zone setup; 32 zones with Amp or Preamplifier definition. Toggling Amp/Preamplifier control function. Data-stream filtered © IR receiver (May be defeated). Blue Source Select indicators - tracks the amplifier selection, indicates amplifier ON status.
Part Names and Function Chassis Key Cap bracket Source Keys Set Key Membrane Keypad SKIP USB socket 1 2 3 4 5 6 7 8 9 0 -VOL IR Receiver Learning IR sensor VOL+ System LED & Volume indicator 5
Part Names and Function—Continued Cover Plate Infra-Red Window 6
Part Names and Function—Continued Key Cap Membrane USB Cable Flush Box screws RJ45 Connector CD Tuner Cable DMS AUX DVD MCD VID SAT iPod iPod2 MP3 TIVO XM Sirius SKY DVR FOX WEB Request Imerge PC TAPE Lights CD2 TV Room2 TU2 PROJ SCRN CAM1 CAM2 CAM3 CD-ROM 7
Installation The KEY-5.7 chassis mounts directly to the wall surface. The following steps outline the installation procedure: • Cut out the required mounting hole in the wall above the flush-box. • Terminate a RJ45 plug to the CAT5E cable see wiring instructions on page 8. • Connect the RJ45 plug to the KEY-5.7. • Secure the keypad in position using the supplied flush-box screws. • Program the keypad either manually or via a USB connected PC running Integra Keypad manager. Note: the KEY-5.
System Wiring CAT5E cable terminated with a RJ45 plug is used to connect to the KEY-5.7. Use the standard 568-B color code for the CAT5E termination: Pin # 1 2 3 4 5 6 7 8 Wire Color White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown Keypad function +12V DC supply 0V supply IR output nc Data input 0V supply nc nc 1234 5678 When cabling use CAT5E home runs with a maximum length of 200m. “Daisy chaining” or parallel connection of up to four keypads per CAT5E cable may be used.
System Wiring—Continued Connecting to an Integra Multi-Zone amplifier MZA-4.7 KEY-5.7 keypads are wired to the MZA-4.7 Interface port. Integra controllers - keypad’s may be parallel connected. IR emitters plug into the IR outputs and are fixed to the source equipment’s IR windows. Note: Ports IR1 and IR2 are Interface port specific, while ports IR1+IR2 relay the signals from both interface ports.
Manual Programming The SET Key is used along with the Source Keys to put the keypad into various programming modes. The SET key is pushed first - System LED flashes Green followed by the relevant source or function key.
Manual Programming—Continued LEARN MODE = SET + S1 Before entering Learn mode the required Source Bank should be selected by pushing it’s Source Key. To enter LEARN mode push SET followed by the S1 key, the System LED flashes amber. Push the Key you wish to donate an IR to, system LED stops flashing (Ready to receive an IR code). Place the donating remote approximately 80mm away from the Learning IR sensor and push the remote control key, holding down until the system LED turns green (Code learnt).
Manual Programming—Continued Enter a 3 digit numeric representation of the keypad’s setup: First two digits are the Zone: 00 - 31. The third digit is: 0 = Amplifier Zone, 1 = Preamplifier Zone 2 = Amp & Preamplifier toggle. Typical codes are: 010 = Zone 1 amplifier, 041 = Zone 4 Preamplifier. Once a correct 3-digit sequence is entered Integra mode automatically exits. Alternatively, with a connected MZA-4.7 turn ON and OFF the zone twice.
Manual Programming—Continued LONG PRESS MODE = SET + S5 RESET = SET + S6 + S6 This mode adds a second function to a key already programmed. The second function will be sent by the Keypad if the Key is pushed down longer than 0.7 seconds. Push SET followed by the S5 key to enter Long press mode, the system LED glows amber. Push the key that requires the Long-press function - donate the IR code - the system LED glows green. Exit by pushing the SET key.
Manual Programming—Continued SOURCE INDICATOR DIMMING = SET + –VOL The source indicator brightness may be adjusted: Push SET, then push – VOL to cycle through 25%, 50% and 100% levels. Exit by pushing the SET key. VOLUME LEVEL INDICATOR DIMMING = SET + VOL+ The Volume Level indicator brightness may be adjusted: Push SET, then push the VOL+ to cycle through OFF, 50% and100% levels. Exit by pushing the SET key.
Troubleshooting One source does not operate, or operates intermittently. – Check the IR emitter is OK, ie. Swap it to other source equipment that is being controlled. – Ensure the IR emitter is directly over the source equipment’s IR window. – Check to see if the source gear can be controlled via the IR receiver, If it can then try learning the codes again, ensuring the correct bank has been selected.
Troubleshooting—Continued keypad is functioning correctly ie. Source key flashes when a key with learnt function is pressed. Try replacing the IR emitters - these are readily damaged if connected across the Controller Interfaces power supply. Keypad does not track the MZA4.7. – Ensure the data termination has integrity, and is not shorted to other conductors in the CAT5E. Ensure the keypad is correctly zoned.
Specifications IR Learning Compatible with virtually all brands of remote controls using carrier or modulation frequencies between 20KHz and 500KHz. Also capable of learning non-modulated pulse codes with a minimum pulse width of 10µs. Wiring Up to 200 m of CAT5E home run cable. Memory 12Kbytes - IR codes are stored in Flash memory. Dimensions Cover Plate: Width = 75mm, Height = 120mm, Depth = 4.
Template 1 19
Template 2 21
Memo 23
Integra Division of ONKYO U.S.A. CORPORATION 18 park Way, Upper Saddle River, N.J. 07458, U.S.A. Tel: 201-785-2600 Fax: 201-785-2650 http://www.integrahometheater.com Integra Division of ONKYO CORPORATION Sales & Product Planning Div.: 2-1, Nisshin-cho Neyagawa-shi, OSAKA 572-8540, JAPAN Tel: 072-831-8023 Fax: 072-831-8124 En D0610-1 SN 29344404 (C) Copyright 2006 ONKYO CORPORATION Japan. All rights reserved.