User's Manual

12
Installation instruction
1)
Determine an appropriate position for the Reader
and drill two holes for mounting the reader to the
surface (see mullion mounting drawing on page
12). Do not mount the readers less than 20 cm
(7.87 inch) from each other. Make sure that
enough room to connect the cable is allowed.
Protect the cable against sharp edges and any
damage from chaffing.
2) Remove the Terminal Connector 8 pins from the
back of the Reader. Use a small flat head
screwdriver to loosen off all of the terminals. The
end of the cable should be prepared by cutting it
back to expose the wires and each end should be
twisted to eliminate any loose or frayed wires.
3) The wires should then be connected to the Reader
inline with the Connector Assignments. Wire ends
outside the shielding and optional permanent LED
links should be kept as short as possible.
Note: wires at the connector must be as kept as
short as possible: long, unshielded connections
will reduce the sensitivity of the reader. Twist the
power and ground wires together to avoid creating
magnetic fields.
4) After wiring the reader and the Host system the
Reader is ready to be tested. Apply power and
present a Card to the Reader. The green LED
should flash and the buzzer should beep indicating
a read. If the Host system is connected to the red
and green LED inputs these should follow the
functionality of the Host system.