User's Manual
CamPac2 Operation
M13-0003-00A
28
Choose your Settings
7. After the Campac2 unit powers back on, the
Default screen is displayed.
8. Press ▼(Ent) to bring up the Top Menu
and press the RF Setup option from that
menu. The RF Setup menu is displayed.
9. Scroll down to the TX Power option and
press ▼(Ent). The TX Power screen is
displayed. The field will display either the
Fixed Settings –or – the Standard Fixed
Settings depending on what was chosen
under the System►Power Control option.
10 Press ▼ (Ent) on the Number Field until it
becomes active (turns green) and use the
rotary dial to scroll around the dial and
make your number selection. Press ▼ (Ent)
when you found the correct value.
5.8 MODULATION
(MAIN>MODULATION)
Figure 17: Modulation Options
5.8.1 Constellation
(MAIN>MODLATION>CONSTELLATION)
QPSK
16QAM
64QAM
5.8.2 Code Rate
(MAIN>MODULATION>CODE RATE)
1/2
2/3
3/4
5/6
7/8
5.8.3 Guard Interval
(MAIN>MODULATION>GUARD INTERV)
1/32
1/16
1/8
1/4
5.9 VIDEO SETUP
(MAIN>VIDEO)
Figure 18: Video Setup Options
5.9.1 Input
(MAIN>VIDEO>INPUT)
Figure 19: Video Input Options
5.9.2 Format
(MAIN>VIDEO>FORMAT)
Figure 20: Video Format Options
Constellation
Code Rate
Guard Interval
Input
Format
Test Modes
Options
HDSDI / SDI
Composite
Y Pr Pb
S-Video
Test Modes
Ext ASI (BNC)
Format
NTSC
Frame Rate
29.97 Hz
Chroma