Intel Core2 Duo Desktop Processor, Intel Pentium Processor, and Intel Pentium 4 Processor 6x1 Sequence
Case Temperature Reference Metrology 
92     Thermal and Mechanical Design Guidelines 
5.  Using the microscope and tweezers, bend the tip of the thermocouple at 
approximately 10 degree angle by about 0.8 mm [.030 inch] from the tip 
(
Figure 40). 
Figure 40. Bending the Tip of the Thermocouple 
D.5.2  Thermocouple Attachment to the IHS 
6.  Clean groove and IHS with Isopropyl Alcohol (IPA) and a lint free cloth removing 
all residues prior to thermocouple attachment. 
7.  Place the thermocouple wire inside the groove; letting the exposed wire and bead 
extend about 1.5 mm [0.030 inch] past the end of groove. Secure it with Kapton* 
tape (
Figure 41). Clean the IHS with a swab and IPA. 
8.  Verify under the microscope that the thermocouple wires are straight and parallel 
in the groove and that the bead is still bent. 
Figure 41. Securing Thermocouple Wires with Kapton* Tape Prior to Attach 