Standalone Switch Installation Guide

Getting Started - RAID Array 410 for Windows NT – Intel
1–4 EK–SMRAC–IG. C01
3. Grasping the sheet metal base assembly, carefully lift the rear of the RAID Array 410
enclosure over the “hump” in the center of the pallet and then roll the RAID Array 410
enclosure off the pallet and down the ramp to the floor. If any further lifting of the RAID
Array 410 is required, grasp the sheet metal base assembly on the side and lift it care-
fully.
4. Retain the shipping container and all packing materials.
1.4 Placing the RAID Array 410 Enclosure
Use the following procedure to move the enclosure to its designated site:
WARNING
To prevent damage to the RAID Array and injury to personnel,
make sure to provide a clear path for the casters.
1. Roll the enclosure to the desired location.
2. If required, engage the lock on each front caster to prevent the enclosure from moving.
1.5 Installing the SWXRC-04 Controller and Write-Back Cache Module
Unlock the enclosure, if necessary, using the keys provided. If the SWXRC-04 RAID Array
controller and the write-back cache module have not been installed in your StorageWorks
enclosure, you should install them at this time. Do so by referring to Chapter 3, Installing
the Storage Subsystem, in the SWXRC RAID Array Controller User’s Guide
(EK-SMCS1-UG), included with the subsystem.
If your system is to be configured for dual-redundant controller operation, install the second
controller and associated components at this time . Refer to Chapter 3, Installing the Storage
Subsystem, in the SWXRC RAID Array Controller User’s Guide (EK-SMCS1-UG).
NOTE
Review the information contained in any Release Notes included
with the system. The Release Notes contain version-specific in-
formation, including controller configuration notes. Retain the Re-
lease Notes for future reference.
1.6 Installing the PC (Program) Card in the Controller
CAUTIONS
Follow these precautions and PC (program) card handling guide-
lines when installing or replacing the card. Install the (PC) program
card in the SWXRC-04 RAID controller
after
the controller has
been installed in a properly grounded SWXSC-AA cabinet. Other-
wise, damage to the card may result.
The PC (program) card electrostatic discharge (ESD) shield must
remain installed over the card during controller operation to protect
it from electrostatic discharge that may cause the contents of the
card to be damaged.