Intel Xeon Processor 2.80 GHz Thermal/Mechanical Design Guidelines
Dual-Core Intel
®
 Xeon
®
 Processor 2.80 GHz Thermal/Mechanical Design Guidelines 23
Thermal/Mechanical Reference Design
2.3.2.1 Example
The cooling performance, Ψ
CA,
 is then defined using the principle of thermal characterization 
parameter described above:
• Define a target case temperature T
CASE-MAX
 and corresponding TDP at a target frequency, F, 
given in the processor datasheet.
• Define a target local ambient temperature at the processor, T
LA
. 
Since the processor thermal specifications (T
CASE-MAX
 and TDP) can vary with the processor 
frequency, it may be important to identify the worse case (lowest Ψ
CA
) for a targeted chassis 
(characterized by T
LA
) to establish a design strategy such that a given heatsink can cover a given 
range of processor frequencies.
The following provides an illustration of how one might determine the appropriate performance 
targets. The example power and temperature numbers used here are not related to any Intel 
processor thermal specifications, and are for illustrative purposes only.
Assume the datasheet TDP is 85 W and the case temperature specification is 68 °C for a given 
frequency. Assume as well that the system airflow has been designed such that the local processor 
ambient temperature is 45°C. Then the following could be calculated using equation (2-3) from 
above for the given frequency:
Equation 2-5. Ψ
CA
 = (T
CASE
 – T
LA
) / TDP = (68 – 45) / 85 = 0.27 °C/W
To determine the required heatsink performance, a heatsink solution provider would need to 
determine Ψ
CS
 performance for the selected TIM and mechanical load configuration. If the 
heatsink solution were designed to work with a TIM material performing at Ψ
CS
 ≤ 0.05 °C/W, 
solving for equation (2-4) from above, the performance of the heatsink would be: 
Equation 2-6. Ψ
SA
 = Ψ
CA
 − Ψ
CS
 = 0.27 − 0.05 = 0.22 °C/W
If the local processor ambient temperature is assumed to be 40°C, the same calculation can be 
carried out to determine the new case-to-ambient thermal resistance:
Figure 2-7. Processor Thermal Characterization Parameter Relationships
HEATSINK
IHS
TIM
PROCESSOR
T
S
T
C
SOCKET
Ψ
SA
Ψ
CS
Ψ
CA
HEATSINK
IHS
TIM
PROCESSOR
T
S
T
CASE
T
LA
SOCKET
Ψ
SA
Ψ
CS
Ψ
CA
HEATSINK
IHS
TIM
PROCESSOR
T
S
T
C
SOCKET
Ψ
SA
Ψ
CS
Ψ
CA
HEATSINK
IHS
TIM
PROCESSOR
T
S
T
CASE
T
LA
T
LA
SOCKET
Ψ
SA
Ψ
CS
Ψ
CA