Intel Xeon Processor and Intel E7500/E7501Chipset Compatible Platform Design Guide
Intel
®
 Xeon™ Processor and Intel
®
 E7500/E7501 Chipset Compatible Platform Design Guide 247
Layout Checklist
14.2 Processor Power Delivery Layout Checklist 
All recommendations in this checklist apply to the power distribution design of the processor’s 
“VCC_CPU” and ground supply. This checklist assumes the voltage regulator solution adheres to 
the guidelines documented in either the 
VRM 9.1 DC-DC Converter Design Guidelines or Dual 
Intel
®
 Xeon™ Processor Voltage Regulator Down (VRD) Design Guidelines depending on which 
solution is implemented.
Table 14-2. Processor Power Delivery Layout Checklist (Sheet 1 of 4)
Checklist Items Recommendations Comments
Power / Ground 
Plane Copper 
Weight
• Use at least 2 oz total copper for the 
combined weight of all processor power 
planes (VCC_CPU).
• Use at least 2 oz copper for the combined 
weight of all processor ground planes.
• These layers can be implemented using two 
1 oz copper layers or four ½ oz copper 
layers.
• Refer to Section 11.2.2.
Power / Ground 
Plane Geometry
• The power / ground supply to both processor 
sockets can be distributed as a dedicated 
layer of the PCB, a voltage supply plane with 
other power islands, or an island on a signal 
layer.
• Never distribute processor power with 
traces.
• Do not route capacitors to the processor 
socket using traces.
• The island or plane connecting the Voltage 
Regulator Module (VRM) or Voltage 
Regulator Down (VRD) supply to both 
processor sockets should not have any 
breaks or voids.
• A “trace” is any etch that is less 
than the width of the processor 
socket.
Power / Ground 
Plane Processor 
Socket Breakout
• The power / ground planes should 
completely surround all of the pins of the 
VRM or VRD and processor socket.
• Minimize the size of the processor socket 
vias anti-pads where possible. Anti-pads 
should be no larger than 35 mils. 
• Locations of the capacitor pads on the outer 
power layer should not hinder power 
distribution by creating a “slot”-shaped 
geometry in the plane.
• Avoid vias around the socket breakout area 
as much as possible.
• Refer to Section 11.2.2.
• Section 11.2.2 contains an 
example of good socket power / 
ground plane routing for an inner 
layer.
Voltage Regulator Placement and Sense / Feedback Lines
VRM-based 
topology
• Use the “Row” pattern topology. • Refer to Section 11.2.4.
VRD-based 
topology
• Use the “L” pattern or “Row” pattern 
topology.
• Refer to Section 11.2.5.1
VRD sense point • Route the VRD’s voltage sense input signal 
to the middle of the VCC_CPU plane. The 
location of this plane connection and route is 
not critical.
• Refer to Section 11.2.5.3.