Intel Xeon processor LV Thermal Design Guide
Reference Thermal Solutions
Dual-Core Intel
®
 Xeon
®
 processor LV and ULV
Thermal Design Guide August 2006
30 Reference Number: 311374-002
It is important to realize that the thermal interface material degrades over time and 
exposure to environmental effects. Figure 13, Figure 15, and Figure 17 show the 
junction-to-ambient thermal performance assuming the “end of life” performance for 
the reference TIM. End of life usually occurs in to 5 to 7 years. Actual test data may 
differ from the values shown since the TIM thermal resistance will be comparable to the 
“beginning of life” impedance. It is common for the TIM impedance to increase 
significantly over time (i.e., > 2x). The end user must ensure that they account for the 
TIM thermal performance over the expected lifetime of the computing system.
6.6 Heatsink Orientation
All of the heatsinks were designed to maximize the available space within the 
volumetric keep-out zone and their respective form factor limitations. These heatsinks 
must be oriented in a specific direction relative to the processor keep-out zone and 
airflow. In order to use these designs, the processor must be placed on the PCB in an 
orientation so the heatsink fins will be parallel to the airflow. Figure 18 illustrates this 
orientation.
6.7 Dual Processor Considerations
The heatsink designs presented are suitable for use in dual-processor configurations. 
However additional precautions must be taken with the orientation of the processors on 
the motherboard. The results of computer modeling and testing indicate that 
processors placed in series, that is one processor placed directly behind the other 
relative to the airflow, will have a higher CPU temperature when compared to 
processors placed in parallel (side-by-side relative to the airflow). As a result, it is 
strongly recommended that the processors be placed in the parallel configuration for 
optimized thermal performance. For a better understanding, Figure 18 illustrates the 
preferred configuration.