1.4.2  Termination and Routing Guidelines 
Table 6. Recommended Debug Port Signal Terminations 
Signal Termination Value  Termination 
Voltage 
Termination 
Location 
Notes 
BCLK(p/n)      1 
DBA#  150 – 240 Ω 5%  VCC of target 
system recovery 
circuit. 
Within 1 ns of debug 
port 
2 
DBR#  150 – 240 Ω 5%  VCC of target 
system recovery 
circuit 
Within 1 ns of debug 
port 
FBO  Connect to TCK pin at the 
closest BPM[5:0]# bus load 
device 
NA NA   
TCK 27 Ω 1%  GND  Within 200 ps of the 
debug port 
TMS 39 Ω 1 %  VTAP  Within 200 ps of the 
debug port 
TDI 150 Ω 5%  VTAP  Within 300 ps of the 
receiver 
3 
TDO 75 Ω 5%  VTAP  Within 300 ps of the 
debug port 
3 
TRST#  500 – 680 Ω 5%  GND     
BPM[5:0]#   Characteristic impedance of 
transmission line 
VTERM  6 
RESET#      1, 5 
Vtt N/A      4 
All Other 
Signals 
N/A N/A N/A  
NOTES:   
1.  Resistance, voltage, and termination location are defined in the Platform Design Guide documentation. 
Appendix D is not valid for ITP700 Flex. 
2.  Only required if DBA# is used with any target system circuitry. This signal may be left unconnected if 
unused 
3.  A termination resistor must be located at the receiver of each scan chain agent. 
4.  Mount debug port directly over the Vtt plane. Connect plane with vias and short, wide traces to Vtt (pins 
27 and 28). If a plane is not available, add a 0.1 µF ceramic cap between Vtt and GND within 0.1 inches 
of the Vtt pins of the debug port. 
5.  See Figure 3. ITP700 Flex Required Layout of Reset 
6.  See Figure 4. ITP700 Flex Required Layout of BPM[5:0]# 
The most radical difference between the standard ITP700 and ITP700 Flex implementation 
guidelines is the termination requirements for the BPM[5:0]# signals. For ITP700 Flex the 
terminations on the debug port end of the transmission line are built into the ITP700 Flex device. 
Note that this means that there is no termination on BPM[5:0]# if the ITP700 Flex is not installed. 
If the platform designers require these signals to be terminated when ITP700 Flex is not installed it 