Voltage Regulator Module (VRM) and Enterprise Voltage Regulator-Down (EVRD) 10.0 Design Guidelines
VRM and EVRD 10.0 Design Guidelines 
R
12   
Table 1. Icc Guidelines 
Icc(TDC) (A)  Icc(Max) (A)  Icc(Step) (A)  Slew Rate (A/µs) 
Intel® Xeon™ Processor with 
800 MHz System Bus 
85 100 70  560 
Low Voltage Intel® Xeon™ 
processor with 800 MHz 
system bus 
56 60 38.5  308 
NOTES:   
1. See the Intel® Xeon™ Processor with 800 MHz System Bus Datasheet and Low Voltage Intel® Xeon™ 
processor with 800 MHz System Bus Datasheet for the latest specifications. 
2.  This table represents the expected operating limitations for VRM/EVRD 10.0. Future Intel® Xeon™ 
processors with 800 MHz system bus will require a later version of the VRM/EVRD to reach end-of-life 
capabilities. 
2.2 Load Line Definitions  REQUIRED 
The following load lines contain static and transient voltage data as well as maximum and 
minimum voltage levels. Measurement of the load line is to be done at the remote sense point. It 
is required that the remote sense point for the voltage regulator be connected to the processor 
VCCSENSE and VSSSENSE pins. 
The upper and lower load lines represent the allowable range of voltages that must be presented to 
the processor. The voltage must never exceed these boundaries for proper operation of the 
processor. 
Figure 3 shows load line voltage offsets and current levels based on the VID specifications. 
Figure 3. VRM/EVRD 10.0 Die Load Line 
-0.180
-0.160
-0.140
-0.120
-0.100
-0.080
-0.060
-0.040
-0.020
0.000
020406080100
Icc (A)
Vcc (V) (Offset from VID)
Vmax
Vmin
The following equations for the load lines are valid for the range of load current from 0 to 100A. 
•  V
MAX
 load line: Vcc = VID – (1.25 mΩ • Icc) 
•  V
MIN
 load line: Vcc = VID – 0.040V – (1.25 mΩ • Icc) 