Specification Sheet

50
2.7 Reliability
The Mean Time between Failures (MTBF) predictions are calculated using component and
subassembly random failure rates. The calculation is based on the Telcordia SR-332 Issue 2,
Method I, Case 3, 55 ºC ambient. The MTBF prediction is used to estimate repair rates and spare
parts requirements. The MTBF for Intel NUC8i3BEB board is 62,994 hours. The MTBF for Intel
NUC8i5BEB board is 63,369 hours. The MTBF for Intel NUC8i7BEB board is 64,998 hours.
2.8 Environmental
Table 33. Environmental Specifications lists the environmental specifications for the board.
Table 33. Environmental Specifications
Parameter Specification
Temperature
Non-Operating
-40 °C to +60 °C
Operating
0 °C to +50 °C
The operating temperature of the board may be determined by measuring the air
temperature from the junction of the heatsink fins and fan, next to the attachment screw,
in a closed chassis, while the system is in operation.
Shock
Unpackaged
50 g trapezoidal waveform
Velocity change of 170 inches/s²
Packaged
Free fall package drop machine set to the height determined by the weight of the package.
Product Weight (pounds) Free Fall (inches)
<20
36
21-40
30
41-80
24
81-100 18
Vibration
Unpackaged
5 Hz to 20 Hz: 0.01 g² Hz sloping up to 0.02 g² Hz
20 Hz to 500 Hz: 0.02 g² Hz (flat)
Packaged 5 Hz to 40 Hz: 0.015 g² Hz (flat)
40 Hz to 500 Hz: 0.015 g² Hz sloping down to 0.00015 g² Hz
Acoustic
Cool Setting
4.5 BA (~35dBA)
100% duty (@3400
RPM)
5.7BA (~47dBA)
Note: Before attempting to operate this board, the overall temperature of the board must be above the minimum
operating temperature specified. It is recommended that the board temperature be at least room temperature
before attempting to power on the board. The operating and non-operating environment must avoid condensing
humidity.