Specification Sheet

Datasheet, Volume 1 of 2 107
Thermal Management
5.4.4 Thermal Metrology
The maximum TTV case temperatures (T
CASE-MAX
) can be derived from the data in the
appropriate TTV thermal profile earlier in this chapter. The TTV T
CASE
is measured at the
geometric top center of the TTV integrated heat spreader (IHS). Figure 5-5 illustrates
the location where T
CASE
temperature measurements should be made.
The following supplier can machine the groove and attach a thermocouple to the IHS.
The following supplier is listed as a convenience to Intel's general customers and may
be subject to change without notice. THERM-X OF CALIFORNIA, 3200 Investment Blvd,
Hayward, Ca 94544. George Landis +1-510-441-7566 Ext. 368 george@therm-x.com.
The vendor part number is XTMS1565.
5.4.5 Fan Speed Control Scheme with Digital Thermal Sensor
(DTS) 1.1
To correctly use DTS 1.1, the designer must first select a worst case scenario T
AMBIENT
,
and ensure that the Fan Speed Control (FSC) can provide a Ψ
CA
that is equivalent or
greater than the Ψ
CA
specification.
The DTS 1.1 implementation consists of two points: a Ψ
CA
at T
CONTROL
and a Ψ
CA
at
DTS = -1.
12 54.3 32 64.5
14 55.3 34 65.5
16 56.4 35 66.1
18 57.4
Table 5-11. Thermal Test Vehicle Thermal Profile for PCG 2015B Processor (Sheet 2 of 2)
Power (W) T
CASE_MAX
(C) Power (W) T
CASE_MAX
(C)
Figure 5-5. Thermal Test Vehicle (TTV) Case Temperature (T
CASE
) Measurement Location