Intel Core2 Duo Desktop Processor, Intel Pentium Processor, and Intel Pentium 4 Processor 6x1 Sequence
Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines 85
Appendix D Case Temperature
Reference Metrology
D.1 Objective and Scope
This appendix defines a reference procedure for attaching a thermocouple to the IHS
of a 775-land LGA package for T
C
measurement. This procedure takes into account the
specific features of the 775-land LGA package and of the LGA775 socket for which it is
intended. The recommended equipment for the reference thermocouple installation,
including tools and part numbers are also provided. In addition a video Thermocouple
Attach Using Solder – Video CD-ROM is available that shows the process in real time.