Note
Application Note 19
6 Related Specifications
Operating temperature: Between 10° C and 50° C
Electrostatic Discharge (ESD) Environment: Controlled to less than 300 volts
Table 6-1. Electrical Operating Parameters
Symbol Parameter Value Units
Vccp Applied Voltage (Powered) 0.8 to 1.2 max V
CtrlOnThres Switch On Threshold 300 mV
HctrlEnVih High Switch Enable VIH (Powered) Vccp + 0.6 max V
LctrlEnVih Low Switch Enable VIH (Powered) Vccp + 0.6 max V
CtrlDisVil Switch Disable VIL 0.0 V
CtrlEnVih Switch Enable Voltage (Un-powered) 1.2 max V
Sd(on) Switch Control On To Signal Out Delay (Powered) 20 us
Sd(off) Switch Control Off To Signal Out Delay (Powered) 20 us
Rval Resistor Value (Un-Powered) 1k(+-5%) Ω
RvalControl Resistor Value of Four Control Signals (Un-Powered) 1k(+5%, -40%) Ω
Hid(on) High Switch On Saturation Current 20 mA
Lid(on) Low Switch On Saturation Current 26 mA
Table 6-2. Test Condition for High Side Switch (Powered Digital)
Symbol Parameter Value Units
Vccp Applied Voltage 1.2 max V
Hcontrol Enable High Side Switch 1.8 max V
Lcontrol Disable Low Side Switch 0.0 V
Signal Minimum VOH 600 mV
Signal Load Current Source from Signal to Ground (Pull Down) 5 mA
Signal VohTh Test VOH Threshold Setting 400 mV
Signal VolTh Test VOL Threshold Setting 400 mV