H23. MOVD Following Zeroing Instruction Can Cause Incorrect
Result
Problem: An incorrect result may be calculated after the following circumstances occur:
1. A register has been zeroed with either a SUB reg, reg instruction or an XOR reg, reg instruction
2. A value is moved with sign extension into the same register’s lower 16 bits; or a signed integer multiply is
performed to the same register’s lower 16 bits
3. This register is then copied to an MMX™ technology register using the MOVD instruction prior to any other
operations on the sign-extended value.
Specifically, the sign may be incorrectly extended into bits 16-31 of the MMX technology register. Only the MMX
technology register is affected by this erratum.
The erratum only occurs when the 3 following steps occur in the order shown. The erratum may occur with up to
40 intervening instructions that do not modify the sign-extended value between steps 2 and 3.
1. XOR EAX, EAX
or SUB EAX, EAX
2. MOVSX AX, BL
or MOVSX AX, byte ptr <memory address> or MOVSX AX, BX
or MOVSX AX, word ptr <memory address> or IMUL BL (AX implicit, opcode F6 /5)
or IMUL byte ptr <memory address> (AX implicit, opcode F6 /5) or IMUL AX, BX (opcode 0F AF /r)
or IMUL AX, word ptr <memory address> (opcode 0F AF /r) or IMUL AX, BX, 16 (opcode 6B /r ib)
or IMUL AX, word ptr <memory address>, 16 (opcode 6B /r ib) or IMUL AX, 8 (opcode 6B /r ib)
or IMUL AX, BX, 1024 (opcode 69 /r iw)
or IMUL AX, word ptr <memory address>, 1024 (opcode 69 /r iw) or IMUL AX, 1024 (opcode 69 /r iw)
or CBW
3. MOVD MM0, EAX
Note that the values for immediate byte/words are merely representative (i.e., 8, 16, 1024) and that any value in
the range for the size may be affected. Also, note that this erratum may occur with “EAX” replaced with any 32-
bit general purpose register, and “AX” with the corresponding 16-bit version of that replacement. “BL” or “BX”
can be replaced with any 8-bit or 16-bit general purpose register. The CBW and IMUL ( opcode F6 /5 )
instructions are specific to the EAX register only.
In the example, EAX is forced to contain 0 by the XOR or SUB instructions. Since the MOVSX, IMUL and CBW
instructions listed should modify only bits 15:8 of EAX by sign extension, bits 31:16 of EAX should always
contain 0. This implies that when MOVD copies EAX to MM0, bits 31:16 of MM0 should also be 0. Under certain
scenarios, bits 31:16 of MM0 are not 0, but are replicas of bit 15 (the 16th bit) of AX. This is noticeable when the
value in AX after the MOVSX, IMUL or CBW instruction is negative, i.e., bit 15 of AX is a 1.
When AX is positive (bit 15 of AX is a 0), MOVD will always produce the correct answer. If AX is negative (bit 15
of AX is a 1), MOVD may produce the right answer or the wrong answer depending on the point in time when
the MOVD instruction is executed in relation to the MOVSX, IMUL or CBW instruction.
Implication:
The effect of incorrect execution will vary from unnoticeable, due to the code sequence
discarding the incorrect bits, to an application failure. If the MMX technology-enabled application in which
MOVD is used to manipulate pixels, it is possible for one or more pixels to exhibit the wrong color or position
momentarily. It is also possible for a computational application that uses the MOVD instruction in the manner
described above to produce incorrect data. Note that this data may cause an unexpected page fault or general
protection fault.
Workaround: There are two possible workarounds for this erratum: