Uncore Manual

4 Reference Number: 329468-002
2.4.4 HA Box Events Ordered By Code...............................................................59
2.4.5 HA Box Common Metrics (Derived Events) .................................................60
2.4.6 HA Box Performance Monitor Event List .....................................................60
2.5 Memory Controller (iMC) Performance Monitoring...................................................76
2.5.1 Overview of the iMC................................................................................76
2.5.2 Functional Overview................................................................................76
2.5.3 iMC Performance Monitoring Overview.......................................................77
2.5.3.1 iMC PMON Registers - On Overflow and the Consequences
(PMI/Freeze) ............................................................................77
2.5.4 iMC Performance Monitors........................................................................78
2.5.4.1 MC Box Level PMON State ..........................................................78
2.5.4.2 MC PMON state - Counter/Control Pairs........................................79
2.5.5 iMC Performance Monitoring Events...........................................................81
2.5.5.1 An Overview:............................................................................81
2.5.6 iMC Box Events Ordered By Code..............................................................81
2.5.7 iMC Box Common Metrics (Derived Events) ................................................83
2.5.8 iMC Box Performance Monitor Event List ....................................................84
2.6 IRP Performance Monitoring ................................................................................99
2.6.1 Overview of the R2PCIe Box.....................................................................99
2.6.2 IRP Performance Monitoring Overview .......................................................99
2.6.3 IRP Performance Monitors........................................................................99
2.6.3.1 IRP Box Level PMON State........................................................100
2.6.3.2 IRP PMON state - Counter/Control Pairs......................................100
2.6.4 IRP Performance Monitoring Events.........................................................101
2.6.4.1 An Overview...........................................................................101
2.6.5 IRP Box Events Ordered By Code............................................................101
2.6.6 IRP Box Performance Monitor Event List...................................................102
2.7 Power Control (PCU) Performance Monitoring ......................................................109
2.7.1 Overview of the PCU .............................................................................109
2.7.2 PCU Performance Monitoring Overview ....................................................109
2.7.2.1 PCU PMON Registers - On Overflow and the Consequences
(PMI/Freeze) ..........................................................................110
2.7.3 PCU Performance Monitors.....................................................................110
2.7.3.1 PCU Box Level PMON State.......................................................111
2.7.3.2 PCU PMON state - Counter/Control Pairs.....................................111
2.7.4 PCU Performance Monitoring Events........................................................114
2.7.4.1 An Overview:..........................................................................114
2.7.5 PCU Box Events Ordered By Code ...........................................................115
2.7.6 PCU Box Common Metrics (Derived Events)..............................................117
2.7.7 PCU Box Performance Monitor Event List..................................................118
2.8 Intel® QPI Link Layer Performance Monitoring.....................................................131
2.8.1 Overview of the Intel® QPI Box..............................................................131
2.8.2 Intel® QPI Performance Monitoring Overview...........................................131
2.8.2.1 QPI PMON Registers - On Overflow and the Consequences
(PMI/Freeze) ..........................................................................131
2.8.3 Intel® QPI Performance Monitors............................................................132
2.8.3.1 Intel® QPI Box Level PMON State .............................................133
2.8.3.2 Intel® QPI PMON state - Counter/Control Pairs ...........................133
2.8.3.3 Intel® QPI Registers for Packet Mask/Match Facility.....................134
2.8.3.4 Intel® QPI Extra Registers - Companions to PMON HW.................138
2.8.4 Intel® QPI LL Performance Monitoring Events...........................................139
2.8.4.1 An Overview...........................................................................139
2.8.5 QPI LL Box Events Ordered By Code........................................................139
2.8.6 QPI LL Box Common Metrics (Derived Events) ..........................................141
2.8.7 QPI LL Box Performance Monitor Event List ..............................................143
2.9 R2PCIe Performance Monitoring.........................................................................163
2.9.1 Overview of the R2PCIe Box...................................................................163