WHCK Report

Errata and Contingencies
Test Notes
Operating System
Failing Test
Expiry Date
ID
Number
Type
Error Description
Windows 8 64-bit
Single
Computer
Display Object
test
08/01/2013 884
Erratum
AllInOne desktop computers have the
"Computer.AllInOne" form factor. For this form
factor, the test should recognize the mouse and
keyboard to be external to the main computer
machine. Without this filter it expects the
mouse/keyboard to be part of the computer which
may not be the case.
t.
Windows 8 64-bit
UAA Test
(System)
7/1/2013 244
Contingency
Section 3.3.14 of the Intel High Definition Audio
specification mandates a reset value of 0 for the Interrupt
Control register on HD Audio controllers.
Windows 8 64-bit
UAA Test
(System)
7/1/2014 354
Contingency
The FIFO size for Input and Output Stream Descriptors
should be read only.
Windows 8 64-bit
PCI Hardware
Compliance
Test For
Systems
01/01/2015 13
Contingency
Legacy hardware filter.
Operating System
Test
Description
Windows 8
BIOS
download
Internal: http://bios.intel.com/downloads/
External: http://www.intel.com/ click on Support and Download
Windows 8
BIOS setup Please make sure the BIOS setting are as below, otherwise use default
settings.
System Date and Time: Current date and time
Peripheral Configuration: Enable all onboard component
Drive Configuration: Set to AHCI
Chipset Configuration: Enable HPET
ACPI Suspend State: Set to <S3 State>
Boot Device Priority: set <Hard Disk Driver> to first
Enhanced Consumer IR (CIR) component: Enable
Windows 8 filter
update
WHCK WHQL
test
https://sysdev.microsoft.com/member/SubmissionWizard/LegalExemptions/HC
KFilterUpdates.cab
Special H/W that
use to PASS the
test
None
None