PLMP Report
Errata and Contingencies
Operating System
Failing Test
Expiry
Date
ID
Number
Type
Error Description
Windows 7
Windows 7 64-bit
PCI Hardware
Compliance
Test For
Systems
12/31/2010
753
Erratum
Errata 753 Assertion 3EF27DC9-463F-4712-857B-
0321832E7383 Bit range 23:0 (Organizationally Unique
Identifier)in the Serial Number 1st DW register (offset 4h) in the
Device Serial Number Capability table cannot have a value of 0h
as it must contain a value assigned by IEEE.
Windows 7
Windows 7 64-bit
PCI Hardware
Compliance
Test For
Systems
12/1/2010
1241
Erratum
This happens because the PCI Compliance test assumes that if
the Data Link Layer Link Active Reporting Capable bit in the Link
Capabilities register for a given PCIe port is set then that
indicates that the Data Link Layer Link Active bit will also be set.
This is an incorrect assumption because the Data Link Link
Layer Link Active bit can be reset when there is no device
below the port. This assertion needs to be removed from the
PCIHCT. The current architecture of the PCIHCT prevents it from
knowing whether devices exist below a bridge/port.
Windows 7
Windows 7 64-bit
PCI Hardware
Compliance
Test For
Systems
12/1/2010
401
Erratum
The following PCI Compliance test failure is acceptable: Bit 15
(Bridge Configuration Retry Enable) in the Device Control
register (offset 8h) in the PCI Express Capability table must be
read-only and always return 0 as it is reserved for devices other
than PCI Express to PCI/PCI-X Bridges. Assertion 13A41D3E-
2576-41DC-A67C-525DA3637CEA This failure is acceptable
because this is a PCIe 1.1 feature and the WLP requires
compliance with only PCIe 1.0a.
Windows 7
1) GlitchFree
WMV HD 720p
video playback
quality test
6/1/2010
1245
Erratum
SYSFUND-0062 Case 2 and 3 were added to enhance the
verification of the video playback test. These cases will be in
preview state until this errata expires. If cases 2 or 3 of the
GFHD test fail for any reason while this errata is active, then
the failures should be fitered out. Cases 0 and 1 do not apply to
this errata and remain a requirement
Windows 7
Windows 7 64-bit
1) Graphis HDMI
System Test
(Manual)
12/31/2010
1945
Erratum
Failure is due to the ELDv2 PortId not matching the graphics
adapter LUID. This cannot be enforced currently. In the future,
video drivers will be required to program the ELDv2 PortId with
either, The AdapterLUID for the corresponding display adapter -
OR- 0