WHC report

Errata and Contingencies
Operating System
Failing Test
Expiry
Date
ID
Numb
er
Type
Error Description
Windows 8 64-bit
Single
Computer
Display Object
test
08/01/2013 884
Errata
AllInOne desktop computers have the "Computer.AllInOne"
form factor. For this form factor, the test should recognize
the mouse and keyboard to be external to the main computer
machine. Without this filter it expects the mouse/keyboard to
be part of the computer which may not be the case. t.
Window7 32-bit
Window 7 64-bit
Windows 8 64-bit
UAA Test
(System)
10/1/2013 244
Errata
Section 3.3.14 of the Intel High Definition Audio specification
mandates a reset value of 0 for the Interrupt Control register
on HD Audio controllers.
Window7 32-bit
Window 7 64-bit
Windows 8 64-bit
UAA Test
(System)
7/1/2014 354
Contingency
The FIFO size for Input and Output Stream Descriptors should
be read only.
Window7 32-bit
Window 7 64-bit
Windows 8 64-bit
UAA Test
(System)
3/31/2014 1039
Errata
The FIFO size for Input and Output Stream Descriptors should
be read only.
Window 8 64-bit
USB Exposed
Port System
Test
09/30/2013 1435
Auto Triage
The USB Esposed Port Controller Test is known to fail
without logs in certain configurations using the xHCI
Controller on this system. Please right-click the failed task to
review the Error information. If the task failed with ExitCode
c0000374, a manual erratum might apply. Before using the
manual erratum, it is necessary to review the
PortMappingFinder.wtl log for the Port Mapping Tool task. If
the log contains any 'No companion port for SuperSpeed port'
errors, please contact the xHCI Controller vendor for a
firmware update and do not attempt to use the manual
erratum. If there are no errors, but there is a 'Couldn't get
connector properties for hub' message, please use Manual
Errata 1435 in a Readme form. The erratum will only be
honored if this AutoTriage filter applies to the Run Test task.
Window 8 64-bit
USB3
Termination
10/01/2013 1407
Errata
The USB3 Termination test may fail to find the USB 3.0
(Super Speed) device if the system's USB ports are not
numbered contiguously. While nearly all systems have
contingous USB port numbers, it is not technically required. If
this filter allows the FindUsb3Device task to pass, then HCK
Errata ID 1407 can be used in a Readme form to overturn the
remaining cancelled tasks.
Windows 8 64-bit
xHCI Debug
Capability
Compliance
(Logo)
07/31/2014 316
Contingency
The XHCI Debug Capability Compliance Test will fail XHCI
controllers that do not provide the debug capability registers.
Windows 8 64-bit
xHCI Debug
Capability
Compliance
(Logo)
12/31/2013 566
Errata
The XHCI Debug Capability Compliance Test will fail XHCI
controllers that do not provide the debug capability registers.