Alert Standard Format (ASF) Specification

Alert Standard Format (ASF) Specification v2.0 DMTF Document DSP0136
DSP0136 23 April 2003 Page 64 of 94
Status
Value
“Get
Event
Status”
Rd Byte
Count
Status Type Status Description
0000b
0Bh to
10h
9
Deasserted (no
send)
The event is in the deasserted state, but the ASF-sensor does
not want a PET to be sent on this condition. This will typically be
used when a device sets its initial status upon initialization. The
alert-sending device uses this state information to update its
state tracking information, but does not generate a PET on a
change.
0001b
0Bh to
10h
9
Asserted (no
send)
The event is in the asserted state, but the ASF-sensor does not
want a PET to be sent on this condition. This will typically be
used when a device sets its initial status upon initialization. The
alert-sending device uses this state information to update its
state tracking information, but does not generate a PET on a
change.
0010b
0Bh to
10h
Deasserted
(send)
A deassertion event should be sent when the alert-sending
device either first accesses this device, or detects a change to
this state during operation.
0011b
0Bh to
10h
Asserted
(send)
An assertion event should be sent when the alert-sending
device either first accesses this device, or detects a change to
this state during operation.
0100b
02h (or
0Bh to
10h
10
)
Disabled
The device is present within the ASF-sensor, but its associated
event has been disabled via hardware or software methods.
0101b
02h (or
0Bh to
10h
10
)
Undetermined
The sensor device has not yet assessed the present event
state, possibly because the device is initializing.
0110b Reserved Reserved for future definition by this specification.
0111b 02h
Event Status
End
The ASF-sensor has no device associated with either the value
specified in Event Status Index or any higher value.
1000b
to
1111b
Reserved Reserved for future definition by this specification.
9
The ASF-sensor transmits the PET fields for these Status Value codes to enable
implementations to optionally support start-up state logging.
10
Any data that an ASF-sensor might return with this Status Type is undefined and should not be
interpreted by the message initiator. This function is provided to allow possible simplification of
an ASF-sensor device’s state-machine implementation.