Alert Standard Format (ASF) Specification
Alert Standard Format (ASF) Specification v2.0 DMTF Document DSP0136
DSP0136 23 April 2003 Page 94 of 94
#### Description
SF51
The system identifies all fixed-address SMBus devices that are undiscoverable,
including legacy devices, using a Fixed SMBus Addresses (SEEPROM Record
Type 06h) record in an SMBus SEEPROM.
Optional
SF52
The system identifies all fixed-address SMBus devices, even those that are
discoverable.
Optional
SF53
If the system includes legacy alert-source devices, and those devices’ alerts are
to be handled by an ASF-aware alerting device, the system identifies the legacy-
device alert capabilities using an ASF Legacy-Device Alerts (SEEPROM Record
Type 07h) record in an SMBus SEEPROM.
Optional
SF55
If the system includes devices that provide ASF RMCP system actions to an ASF-
aware alerting device, the system identifies the access methods using an ASF
Remote Control (SEEPROM Record Type 08h) record in an SMBus SEEPROM.
Optional