1.11 Hardware Management Subsystem
The hardware management features enable the board to be compatible with the Wired
for Management (WfM) specification. The board has several hardware management
features, including the following:
Fan monitoring and control
Thermal and voltage monitoring
Chassis intrusion detection
1.11.1 Hardware Monitoring and Fan Control
The features of the hardware monitoring and fan control include:
The Legacy I/O Controller smart fan control, delivering acoustically-optimized
thermal management
Fan speed control controllers and sensors integrated into the Legacy I/O Controller
Four thermal sensors (processor, 82G41 GMCH, 82801GB ICH7, and a remote
thermal sensor)
Power supply monitoring of five voltages (+12 V, +5 V, +3.3 V, +1.125 V, and
+VCCP) to detect levels above or below acceptable values
Thermally monitored closed-loop fan control, for both fans, that can adjust the fan
speed according to thermal conditions
1.11.2 Fan Monitoring
Fan monitoring can be implemented using third-party software. The level of
monitoring and control is dependent on the I/O controller used with the board.
For information about Refer to
The functions of the fan headers Section 1.12.2.2, page 32
Location of the fan headers Figure 6, page 27
1.11.3 Chassis Intrusion and Detection
The board supports a chassis security feature that detects if the chassis cover is
removed. The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion header. When the chassis cover is removed, the mechanical
switch is in the closed position.
For information about Refer to
The location of the chassis intrusion header Figure 10, page 40