8.1.3 Environmental Specification
Item Specification
Operational Temp. -40°C ~ +55°C (w/ optional heating device)
-25°C ~ +55°C (w/o heating device)
Survival Temp. -40°C ~ +80°C
Storage Temp. -40°C ~ +85°C
Storage Environment ETSI EN 300 019 Class 1.1
Operational Humidity Relative humidity range of 10% to 100% non-condensing in accordance
with IEC60068-2-78 for a period of 96 hours.
Non-operational Humidity IEC 60068-2-41 Method Db for a period of 4 hours.
Operational Vibration IEC 60068-2-64,
.01 - .02 PSD, slope +12, 5 to 10 Hz
.02 PSD, slope 0, 10 to 50 Hz
.02 - .001 PSD, slope -12, 50 to 100 Hz
Non-operational Vibration IEC 60721-3-4, Class 4M3 3.0 mm peak (+/- 1.5) (2-9 Hz) 5 m/s2 (9-200 Hz)
IEC 60068-2-6 with test duration of 5 sweeps per each of the 3 axes.
Operational Shock IEC 60068-2-27
Non-operational Shock IEC 60068-2-27
Weather Tightness IP66 per IEC 60529
Lightning Protection IEC 61000-4-5 Class 4
ETSI EN 300 132-2
Hail Impact ASTM E822
Operating Wind Resistance 80 km/hr (50 mph)
Functional Wind Resistance 81-160 km/hr (51 mph ~ 100 mph)
Survival Wind Resistance 161 km/hr ~ 240 km/hr (101 mph ~ 150 mph)
Chemical conditions Per IEC 60068-2-60, Method 4
Lightening IEC 61000-4-2 (ESD)
IEC 61000-4-4 (EFT)
IEC 61000-4-5 (Surge)