Technical Advisory TA 1047
This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory
TA-1047-1
5200 NE Elam Young Parkway
Hillsboro, OR 97124
January 26, 2014
Customers may experience system shutdown and then reboot in
power supply redundancy mode when inserting or removing any one
of the power supply units, or when system encounters unexpected
power supply unit failure.
Products Affected MM#
P4304CR2LFKN 916046
P4304CR2LFJN 916047
P4304CR2LFGN 916048
P4304CR2LFJNL 921563
P4216IP4LHKC 916057
P4216IP4LHJC 916059
P4208IP4LHGC 916062
P4308IP4LHKC 916063
P4308IP4LHJC 916064
P4308IP4LHGC 916065
P4308IP4LHJCL 921562
Description
Intel has identified a scenario that system may experience shutdown and reboot in power supply redundancy mode when
inserting or removing any one of the power supply units, or when system encounters unexpected failure of power supply
unit. Lab testing of AC cycling shows the failure is intermittent and the failure rate to be less than1%.
Intel has determined the Intel○
RE
A Server System P4000IP4 and Workstation System P4000CR2 using power supply
redundancy function with serial number before workweek 02 of 2014 may be affected by this issue. Customers can
identify the workweek by referring to the following example.
The three digits after “UP” in the following figure mean workweek 02 of 2014.
Copyright © 2014 Intel Corporation. * Other names and brands may be claimed as the property of others.