Intel 64 and IA-32 Architectures Software Developers Manual Volume 3B, System Programming Guide Part 2

Table Of Contents
Vol. 3 E-13
INTERPRETING MACHINE-CHECK ERROR CODES
Table E-9. QPI Machine Check Error codes for IA32_MC0_MISC and IA32_MC1_MISC
E.3.2 Internal Machine Check Errors
Table E-10. Machine Check Error codes for IA32_MC7_STATUS
Type Bit No. Bit Function Bit Description
Model specific
errors
1
NOTES:
1. Which of these fields are valid depends on the error type.
7-0 QPI Opcode Message class and opcode from the packet with
the error
13-8 RTId QPI Request Transaction ID
15-14 Reserved Reserved
18-16 RHNID QPI Requestor/Home Node ID
23-19 Reserved Reserved
24 IIB QPI Interleave/Head Indication Bit
Type Bit No. Bit Function Bit Description
MCA error
codes
1
0-15 MCACOD
Model specific
errors
23-16 Reserved Reserved
31-24 Reserved except for
the following
00h - No Error
03h - Reset firmware did not complete
08h - Received an invalid CMPD
0Ah - Invalid Power Management Request
0Dh - Invalid S-state transition
11h - VID controller does not match POC
controller selected
1Ah - MSID from POC does not match CPU MSID
56-32 Reserved Reserved
Status register
validity
indicators
1
57-63