Voltage Regulator-Down (VRD) 10.0

Control Inputs
R
38 VRD Design Guide
Table 18. Voltage Identification (VID) Table
Processor Pins
(0 = low, 1 = high)
Processor Pins
(0 = low, 1 = high)
VID5
VID4
VID3
VID2
VID1
VID0
Vout
(V)
VID5
VID4
VID3
VID2
VID1
VID0
Vout
(V)
0 0 1 0 1 0 0.8375 0 1 1 0 1 0 1.2125
1 0 1 0 0 1 0.8500 1 1 1 0 0 1 1.2250
0 0 1 0 0 1 0.8625 0 1 1 0 0 1 1.2375
1 0 1 0 0 0 0.8750 1 1 1 0 0 0 1.2500
0 0 1 0 0 0 0.8875 0 1 1 0 0 0 1.2625
1 0 0 1 1 1 0.9000 1 1 0 1 1 1 1.2750
0 0 0 1 1 1 0.9125 0 1 0 1 1 1 1.2875
1 0 0 1 1 0 0.9250 1 1 0 1 1 0 1.3000
0 0 0 1 1 0 0.9375 0 1 0 1 1 0 1.3125
1 0 0 1 0 1 0.9500 1 1 0 1 0 1 1.3250
0 0 0 1 0 1 0.9625 0 1 0 1 0 1 1.3375
1 0 0 1 0 0 0.9750 1 1 0 1 0 0 1.3500
0 0 0 1 0 0 0.9875 0 1 0 1 0 0 1.3625
1 0 0 0 1 1 1.0000 1 1 0 0 1 1 1.3750
0 0 0 0 1 1 1.0125 0 1 0 0 1 1 1.3875
1 0 0 0 1 0 1.0250 1 1 0 0 1 0 1.4000
0 0 0 0 1 0 1.0375 0 1 0 0 1 0 1.4125
1 0 0 0 0 1 1.0500 1 1 0 0 0 1 1.4250
0 0 0 0 0 1 1.0625 0 1 0 0 0 1 1.4375
1 0 0 0 0 0 1.0750 1 1 0 0 0 0 1.4500
0 0 0 0 0 0 1.0875 0 1 0 0 0 0 1.4625
1 1 1 1 1 1 OFF
1
1 0 1 1 1 1 1.4750
0 1 1 1 1 1 OFF
1
0 0 1 1 1 1 1.4875
1 1 1 1 1 0 1.1000 1 0 1 1 1 0 1.5000
0 1 1 1 1 0 1.1125 0 0 1 1 1 0 1.5125
1 1 1 1 0 1 1.1250 1 0 1 1 0 1 1.5250
0 1 1 1 0 1 1.1375 0 0 1 1 0 1 1.5375
1 1 1 1 0 0 1.1500 1 0 1 1 0 0 1.5500
0 1 1 1 0 0 1.1625 0 0 1 1 0 0 1.5625
1 1 1 0 1 1 1.1750 1 0 1 0 1 1 1.5750
0 1 1 0 1 1 1.1875 0 0 1 0 1 1 1.5875
1 1 1 0 1 0 1.2000 1 0 1 0 1 0 1.6000
NOTES:
The Vcc output is disabled upon communication of an OFF VID code. This is the same as de-asserting
the output enable input (Section 3.1).
VID [4:0] are compatible with Intel desktop processors using five-bit VID codes.
VID [5:0] will be used on processors with six-bit codes.
3.3 Differential Remote Sense Input (REQUIRED)
The PWM controller must include differential sense inputs to compensate for an output voltage
offset of 300 mV in the power distribution path. The remote sense lines should not draw more
than 10 mA to minimize offset errors. Refer to Section 2.2 for measurement location.