Datasheet
Appendix D: POST Error Beep Codes
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
54 Revision 2.0
Intel order number G17455-004
Appendix D: POST Error Beep Codes
The following table lists POST error beep codes. Prior to system video initialization, the BIOS
uses these beep codes to inform users of error conditions. The beep code is followed by a user-
visible code on POST Progress LEDs.
Table 34. POST Error Messages and Handling
Error Code Error Message Response
0012 CMOS date/time not set Major
0048
Password check failed Major
0140
PCI component encountered a PERR error Major
0141
PCI resource conflict Major
0146 PCI out of resources error Major
5220 CMOS/NVRAM configuration cleared Major
5221
Passwords cleared by jumper Major
5224
Password clear jumper is Set Major
8160
Processor 01 unable to apply microcode update Major
8180 Processor 01 microcode update not found Minor
8190
Watchdog timer failed on last boot Major
8198
OS boot watchdog timer failure Major
8300
Baseboard management controller failed self-test
Major
8305
Hot Swap Controller failure Major
83A0
Management Engine (ME) failed Selftest Major
83A1
Management Engine (ME) Failed to respond. Major
84F2
Baseboard management controller failed to respond Major
84F3
Baseboard management controller in update mode Major
84F4
Sensor data record empty Major
84FF
System event log full Minor
8500 Memory component could not be configured in the selected RAS mode Major
8501 DIMM Population Error Major
8520
DIMM_A1 failed test/initialization Major
8521
DIMM_A2 failed test/initialization Major
8523
DIMM_B1 failed test/initialization Major
8524 DIMM_B2 failed test/initialization Major
8540 DIMM_A1 disabled Major
8541 DIMM_A2 disabled Major
8543
DIMM_B1 disabled Major
8544
DIMM_B2 disabled Major