Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
MSID Mismatch
(MSID Mismatch)
81h All
Processor
07h
Digital Discrete
03h
01 – State Asserted Non-fatal
As and
De
–
Trig
Offset
M –
Processor
Population Fault
(CPU Missing)
82h All
Processor
07h
Digital Discrete
03h
01 – State Asserted Fatal
As and
De
–
Trig
Offset
M –
Processor VRD
Temperature
(P1 VRD Hot)
90h All
Temperature
01h
Digital Discrete
05h
01 - Limit exceeded Fatal
As and
De
–
Trig
Offset
M –
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Threshold
01h
– – – Analog – – –
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Threshold
01h
– – – Analog – – –
Power Supply 2 Fan
Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Threshold
01h
– – – Analog – – –
Power Supply 2 Fan
Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Threshold
01h
– – – Analog – – –
Processor DIMM
Aggregate Thermal
Margin
(Mem P1 Thrm
Mrgn)
B0h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A –